• J Clin Monit Comput · Jun 2010

    Comparative Study

    The mean prehospital machine; accurate prehospital non-invasive blood pressure measurement in the critically ill patient.

    • Sandy Muecke, Andrew Bersten, and John Plummer.
    • Department of Critical Care Medicine, Flinders Medical Centre, Flinders University, Adelaide, SA, Australia. sandra.muecke@flinders.edu.au
    • J Clin Monit Comput. 2010 Jun 1;24(3):191-202.

    ObjectiveNon-invasive blood pressure recordings may be inaccurate in the critically ill patient and measurement difficulties are intensified in the prehospital setting. This may adversely impact upon outcomes for many critically ill patients, particularly those with traumatic brain injury and/or lengthy prehospital times. This study aimed to validate a non-invasive, oscillometric, ambulatory blood pressure measuring device, the Oscar 2, Model 222 (SunTech Medical, Morrisville, USA) during the ambulance transport of critically ill patients.MethodsWe have previously shown that mean arterial blood pressures observed by Intensive Care Unit nurses from a patient monitor can be considered interchangeable with reference intra-arterial integrated mean pressures. In the current study, we compared non-invasive device mean pressures to intra-arterial pressures observed by retrieval nurses from the patient monitor, during the ambulance transportation of critically ill patients. Device performance was required to fulfil the Association for the Advancement of Medical Instrumentation (AAMI) protocol requirements. Additionally, linear mixed effects analyses and Bland-Altman comparisons were undertaken.ResultsFor 157 measurements recorded from 23 patients, when the Oscar 2 did not indicate a measurement was associated with a fault, the device fulfilled the AAMI protocol requirements, with a mean error of -1.1 mmHg (standard deviation 7.8 mmHg), 95% confidence intervals (linear mixed effects analysis) -2.9, 0.8; P = 0.26. Bland-Altman plots indicated uniform agreement across a wide range of blood pressures. Sixteen percent of recordings were associated with a patient, environment, or device generated fault.ConclusionsWhen the Oscar 2 does not indicate a fault has occurred, clinicians may be confident the mean pressure, within acceptable limits, is accurate, even during ambulance motion, administration of high doses of vasopressors and mechanical ventilation. The Oscar 2 appears to be an accurate and rugged out-of-hospital device.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.