• J. Thorac. Cardiovasc. Surg. · Feb 2012

    Younger age and valve oversizing are predictors of structural valve deterioration after pulmonary valve replacement in patients with tetralogy of Fallot.

    • Peter C Chen, Maggie S Sager, David Zurakowski, Frank A Pigula, Christopher W Baird, John E Mayer, Pedro J Del Nido, and Sitaram M Emani.
    • Department of Cardiovascular Surgery, Children's Hospital Boston, Boston, MA 02115, USA.
    • J. Thorac. Cardiovasc. Surg. 2012 Feb 1;143(2):352-60.

    ObjectiveWe sought to identify predictors of structural valve deterioration after pulmonary valve replacement in patients with tetralogy of Fallot.MethodsA retrospective review of 227 patients with tetralogy of Fallot who underwent stented bioprosthetic pulmonary valve replacement at Children's Hospital Boston between 1994 and 2009 was performed. Patient and valve characteristics were assessed as potential predictors of structural valve deterioration by using univariate and multivariable analysis. Freedom from pulmonary valve reintervention and structural valve deterioration were determined by using Kaplan-Meier analysis.ResultsTwo hundred twenty-nine pulmonary valve replacement operations were performed, with no early mortalities. Freedom from reintervention and structural valve deterioration were 94% (95% confidence interval, 87%-100%) and 74% (95% confidence interval, 63%-85%) at 5 years, respectively, and median time to reintervention was 6.4 years (range, 2-10.1 years). Younger age and higher indexed valve internal diameter were predictors of reduced time to structural valve deterioration. Among patients aged less than 20 years at the time of pulmonary valve replacement, indexed valve internal diameter was a significant predictor of increased risk of structural valve deterioration. Valve manufacturer was not a significant predictor of structural valve deterioration.ConclusionsYounger age at the time of pulmonary valve replacement and valve oversizing in patients less than 20 years of age at the time of pulmonary valve replacement were significant predictors of structural valve deterioration and could potentially affect the timing of pulmonary valve replacement and the extent of valve oversizing in small children. No statistically significant difference in valve performance was seen between bioprosthetic valve types at short-term follow-up.Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.