-
J Clin Monit Comput · Feb 2017
ReviewReproducibility of transpulmonary thermodilution cardiac output measurements in clinical practice: a systematic review.
- Raphaël Giraud, Nils Siegenthaler, Paolo Merlani, and Karim Bendjelid.
- Intensive Care Service, Geneva University Hospitals, 4 Rue Gabrielle Perret-Gentil, 1211, Geneva 14, Switzerland. Raphael.Giraud@hcuge.ch.
- J Clin Monit Comput. 2017 Feb 1; 31 (1): 43-51.
AbstractMeasuring cardiac output (CO) is an integral part of the diagnostic and therapeutic strategy in critically ill patients. During the last decade, the single transpulmonary thermodilution (TPTD) technique was implemented in clinical practice. The purpose of this paper was to systematically review and critically assess the existing data concerning the reproducibility of CO measured using TPTD (COTPTD). A total of 16 studies were identified to potentially be included in our study because these studies had the required information that allowed for calculating the reproducibility of COTPTD measurements. 14 adult studies and 2 pediatric studies were analyzed. In total, 3432 averaged CO values in the adult population and 78 averaged CO values in the pediatric population were analyzed. The overall reproducibility of COTPTD measurements was 6.1 ± 2.0 % in the adult studies and 3.9 ± 2.9 % in the pediatric studies. An average of 3 boluses was necessary for obtaining a mean CO value. Achieving more than 3 boluses did not improve reproducibility; however, achieving less than 3 boluses significantly affects the reproducibility of this technique. The present results emphasize that TPTD is a highly reproducible technique for monitoring CO in critically ill patients, especially in the pediatric population. Our findings suggest that obtaining a mean of 3 measurements for determining CO values is recommended.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.