• Eur J Emerg Med · Jun 2013

    Randomized Controlled Trial

    Tracheal intubation during chest compressions performed by qualified emergency physicians unfamiliar with the Pentax-Airwayscope.

    • Dong Hyuk Shin, Sang Kuk Han, Min Seob Sim, and Sang O Park.
    • Department of Emergency Medicine, School of Medicine, Kangbuk Samsung Hospital, Sungkyunkwan University, 108 Pyung-Dong, Jongno-Gu, Seoul 110-746, Korea.
    • Eur J Emerg Med. 2013 Jun 1;20(3):187-92.

    ObjectiveExperienced emergency physicians were recruited and a randomized crossover trial was conducted to compare the performance of the Pentax-Airwayscope (AWS) video-laryngoscope with the Macintosh laryngoscope (McL) for tracheal intubation during continuous chest compressions under three different scenarios: (1) normal airway, (2) limited neck mobility, and (3) tongue edema.MethodsThirty-six experienced emergency physicians performed intubations on a manikin in each of three scenarios. The sequences of scenarios and intubating devices were randomized. Time to complete intubation (primary end point), time to visualization of the vocal cords, the overall success rate, percentage of glottic opening, dental compression, and ease of intubation were determined.ResultsThe times (median [interquartile range]) to complete tracheal intubation were significantly shorter with the AWS than the McL in all three scenarios (11.6 [8.0-14.7] vs. 15.1 [12.8-17.9] s, 13.5 [10.5-20.9] vs. 17.0 [14.1-19.9] s, and 13.6 [11.1-20.9] vs. 15.1 [18.6-37.5] s, respectively). The overall success rates were higher with the AWS than the McL in the difficult intubation scenario (77.8 vs. 100%). The AWS was also more effective than the McL with respect to the percentage of glottic opening, dental compression, and ease of intubation in all three scenarios.ConclusionAlthough participants were experienced emergency physicians familiar with the McL and unfamiliar with the AWS, the AWS proved to be a better tool than the McL to perform tracheal intubation during continuous chest compressions on a manikin. The AWS should be considered as an initial intubating tool to perform tracheal intubation during continuous chest compressions rather than the McL.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…