Clin. Orthop. Relat. Res. · Feb 2012
Randomized Controlled Trial Multicenter StudyCeramic bearings for total hip arthroplasty have high survivorship at 10 years.
- James A D'Antonio, William N Capello, and Marybeth Naughton.
- Greater Pittsburgh Orthopaedics Association, 725 Cherrington Parkway, Suite 200, Moon Township, PA 15108, USA. dantonioja@me.com
- Clin. Orthop. Relat. Res. 2012 Feb 1;470(2):373-81.
BackgroundCeramic bearings were introduced to reduce wear and increase long-term survivorship of total hip arthroplasty. In a previous study comparing ceramic with metal-on-polyethylene at 5 to 8 years, we found higher survivorship and no osteolysis for the ceramic bearings.Questions/PurposesWe asked whether ceramic bearings have equal or superior survivorship compared with that for metal-on-polyethylene at longer followup; we also determined survivorship of the implant systems, the presence or absence of radiographic osteolysis, and incidence of device squeaking.MethodsFive surgeons at five sites have followed 189 patients (216 hips) for a minimum of 10 years and average of 10.3 years (range, 10-12.4 years) comparing alumina ceramic bearings (144 hips) with cobalt chrome-on-polyethylene bearings (72 hips). We determined Kaplan-Meier survivorship of the bearing surface and implant systems and collected radiographic and clinical data.ResultsWe observed no difference between the control metal-on-polyethylene and the alumina-bearing couple cohorts with regard to bearing-related failures (98.9% versus 99.1%). Revisions for any reason occurred in 10.5% of the control patients and 3.1% of the patients with alumina bearings. All femoral implants remain well fixed (100%), whereas one acetabular component (1%) is unstable in the control group. Osteolysis occurred in 26% of the control patients and in none of the patients with alumina bearings. Squeaking occurred in two of 144 hips (1.4%) of the patients with ceramic bearings.ConclusionsPatients receiving the ceramic-on-ceramic bearings had fewer revisions for any reason and less osteolysis than the control metal-on-polyethylene at 10 years. Our data suggest ceramic bearings continue to provide an option for the young and more active patient and provide for a measure to compare other new alternative bearings that are currently available.Level Of EvidenceLevel I, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.