• Anesthesiology · Nov 2008

    Comparative Study

    Comparison between bispectral index and patient state index as measures of the electroencephalographic effects of sevoflurane.

    • Martin Soehle, Richard K Ellerkmann, Matthias Grube, Matthias Kuech, Stefan Wirz, Andreas Hoeft, and Joergen Bruhn.
    • Department of Anesthesiology and Intensive Care Medicine, University of Bonn, Bonn, Germany. martin.soehle@ukb.uni-bonn.de
    • Anesthesiology. 2008 Nov 1;109(5):799-805.

    BackgroundThe Bispectral Index (BIS) and the Patient State Index (PSI) quantify depth of anesthesia by analyzing the electroencephalogram. The authors examined the response of BIS and PSI to sevoflurane anesthesia.MethodsIn 22 patients, sevoflurane anesthesia was induced by inhalation with a tight-fitting facemask and was maintained via a laryngeal mask. Sevoflurane concentrations were increased until burst suppression occurred and subsequently decreased until BIS recovered to values above 60. This procedure was repeated twice until patients underwent intubation for subsequent surgery. End-tidal sevoflurane concentrations, BIS, and PSI were recorded simultaneously. The performance of PSI and BIS to predict the estimated sevoflurane effect site concentration, as derived from simultaneous pharmacokinetic and pharmacodynamic modeling, was compared by determination coefficients (rho(2)) and prediction probabilities (P(K)).ResultsA significant (P < 0.001) correlation between BIS and PSI was found (r(2) = 0.75), and a close sigmoid relation between sevoflurane effect site concentration and both BIS (rho(2) = 0.84 +/- 0.09) and PSI (rho(2) = 0.85 +/- 0.15) was observed. The maximum sevoflurane electroencephalographic effect resulted in PSI values (1.3 +/- 4.3) that were significantly (P = 0.019) lower than BIS values (7.9 +/- 12.1), and the effect site efflux constant k(e0) was significantly smaller (P = 0.001) for PSI (0.13 +/- 0.08 min(-1)) than for BIS (0.24 +/- 0.15 min(-1)). The probability of BIS (P(K) = 0.80 +/- 0.11) to predict sevoflurane effect site concentration did not differ (P = 0.76) from that of PSI (P(K) = 0.79 +/- 0.09).ConclusionsThe BIS reacted faster to changes in sevoflurane concentrations, whereas the PSI made better use of the predefined index range. However, despite major differences in their algorithms and minor differences in their dose-response relations, both PSI and BIS predicted depth of sevoflurane anesthesia equally well.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…