• Pediatrics · Apr 1998

    Randomized Controlled Trial Multicenter Study Comparative Study Clinical Trial

    A randomized comparison of surfactant dosing via a dual-lumen endotracheal tube in respiratory distress syndrome. The Spanish Surfactant Collaborative Group.

    • A Valls-i-Soler, B Fernández-Ruanova, J López-Heredia y Goya, L Román Etxebarría, J Rodriguez-Soriano, and V Carretero.
    • Neonatal Intensive Care Unit, Department of Pediatrics, Hospital de Cruces, Basque University School of Medicine, Bilbao, Bizkaia, Spain.
    • Pediatrics. 1998 Apr 1;101(4):E4.

    AimTo determine if 1-minute instillation of Curosurf via a dual-lumen endotracheal tube without interruption of mechanical ventilation could decrease the incidence of hypoxia (drop in oxygen saturation [SaO2] to <80%, or of transcutaneous partial pressure of oxygen [PtcO2] to <50 mm Hg [6.6 kPa]) and bradycardia (heart rate below 80 beats/minute) at dosing, without affecting the efficacy of the standard bolus delivery.DesignProspective, multicenter, randomized, nonblinded clinical trial.SettingNeonatal intensive care units of the Spanish Surfactant Collaborative Group.Patients And MethodsOne hundred ninety-eight infants (birth weight 600-2000 g) with respiratory distress syndrome needing mechanical ventilation with a fraction of inspired oxygen [FIO2] 0.40 were randomized before 24 hours to receive 200 mg/kg of Curosurf, either by bolus instillation (n = 99) or by a simplified dosing technique (n = 99), giving the full dose in 1 minute via a dual-lumen endotracheal tube without positioning, interruption of mechanical ventilation, or bagging. Two additional doses (100 mg/kg) were given within 12 and 24 hours of first dose, by the same method, if the infant still needed mechanical ventilation and had a FIO2 0.30. The effects of both procedures on the incidence of acute adverse events at dosing, gas exchange, ventilator requirements, and outcome at 28 days were compared.ResultsFewer episodes of hypoxia (18 vs 40% of doses), and a smaller decrease in heart rate and SaO2 were observed in the dual-lumen group. Efficacy of surfactant, based on improvement of oxygenation, ventilator requirements, and number of doses required, was similar in both groups. Infants in the dual-lumen group had a lower total time exposure to supplemental oxygen (195+/-199 vs 266+/-221 hours). No differences in the incidence of air leaks, intraventricular hemorrhage, patent ductus arteriosus, bronchopulmonary dysplasia, or survival were observed.ConclusionA simplified 1-minute Curosurf dosing procedure via a dual-lumen endotracheal tube without fractional doses, ventilator disconnection, changes in the infant's position, or manual bagging was found to reduce the number of dosing-related adverse transient episodes of hypoxia. Although the simplified method appeared to be as effective as bolus delivery, this should be confirmed in a larger trial.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.