Int. J. Pediatr. Otorhinolaryngol. · Feb 2012
Comparative StudyThe laryngeal mask in infants and children: what is the cuff pressure?
- Bryan Schloss, Julie Rice, and Joseph D Tobias.
- Department of Anesthesiology, The Ohio State University, Columbus, OH 43205, United States.
- Int. J. Pediatr. Otorhinolaryngol. 2012 Feb 1;76(2):284-6.
BackgroundUnintended hyperinflation of the cuff of a laryngeal mask airway (LMA) has been associated with increased airway morbidity and postoperative pain. While the manufacturers recommend a cuff pressure of less than 60 cmH(2)O, in usual clinical practice, there is no method used to determine intracuff pressure of an LMA. The purpose of this prospective quality assurance study is to evaluate the incidence of LMA hyperinflation and excessive intracuff pressure in a busy tertiary care pediatric hospital.MethodsThere was no change dictated in clinical practice for these patients. Per our usual practice, the LMA was removed from the package and inserted with the cuff partially inflated. The cuff was further inflated as needed to ensure a seal during positive pressure ventilation to a peak inflating pressure of 20-25 cmH(2)O. During the first 30 min of the case, the pressure in the cuff of the LMA was measured using a hand held manometer. Additional data collected included the patient's demographic data (age, weight, and gender), the size of the ETT, and whether nitrous oxide was in use.ResultsOf the 200 subjects in the current study, 106 had an LMA cuff pressure ≥ 60 cmH(2)O (53%). Patients who were greater than 8 years of age had significantly higher average cuff pressures and significantly more LMAs with an intracuff pressure ≥ 60 cmH(2)O when compared to patients younger than 4 years of age and patients 4-8 years of age. Similarly, larger LMAs were found to have significantly higher intracuff pressures.ConclusionsUsing current clinical practice to inflate the cuff of the LMA, a significant percentage of pediatric patients have an intracuff pressure greater than the generally recommended upper limit of 60 cmH(2)O. Risk factors identified in our study included age of the patient and the size of the LMA.Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.