• Pacing Clin Electrophysiol · Jul 2013

    Multicenter Study Clinical Trial

    Clinical experience and procedural outcomes associated with the DF4 implantable cardioverter defibrillator system: the SJ4 postapproval study.

    • Daniel J Cantillon, Kieu Ha, Robert Styperek, Pitayadet Jumrussirikul, Michael Mirro, Wilson Wong, and Bruce L Wilkoff.
    • Section of Cardiac Electrophysiology and Pacing, Heart and Vascular Institute, The Cleveland Clinic Foundation, Cleveland, Ohio, USA. cantild@ccf.org
    • Pacing Clin Electrophysiol. 2013 Jul 1;36(7):855-62.

    BackgroundCurrent implantable cardioverter defibrillators (ICDs) employ two or three low- and high-voltage lead connectors, adding complexity and bulk, sometimes resulting in incorrect connections and adverse events. The SJ4 study evaluates the performance of a novel integrated single-lead DF4 connection system by characterizing lead measurements, handling characteristics, and outcomes.MethodsPatients with standard guidelines-based ICD indications were enrolled and implanted with a St. Jude Medical™ DF4 system (St. Jude Medical, Sylmar, CA, USA; right ventricular high-voltage DF4 lead models 7120Q, 7121Q, 7122Q, or 7170Q with compatible ICD). Device electrical measurements, handling characteristics, and any adverse events were collected at implant and during each scheduled 6-month follow-up.ResultsAmong 1,701 patients (65 ± 13 years, 72% male, left ventricular ejection fraction 29 ± 12%) enrolled at 58 centers, there were 1,697 successful implants (99.8% implant success; ICD; n = 999, cardiac resynchronization therapy-defibrillator n = 698). Implanting physicians reported that implantation of the DF4 lead was normal or easier than normal in 94% of cases with successful implant. These patients have been followed for 1.7 ± 0.5 years with a maximum follow-up of 2.5 years. The complication rate was 0.017 per patient year of follow-up (95% confidence interval: 0.013-0.023), which included abnormal defibrillation impedance, elevated pacing thresholds, failure to detect ventricular tachycardia/ventricular fibrillation, lead dislodgement, lead fracture, loss of capture, and lead perforation. There were no set screw-related complications at implant or during follow-up.ConclusionThe DF4 system overall performed very well with few complications at implant and in follow-up.©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.