• Crit Care · Jan 2009

    Comparative Study

    Tissue hemoglobin index: a non-invasive optical measure of total tissue hemoglobin.

    • Dean Myers, Michelle McGraw, Mark George, Kristine Mulier, and Greg Beilman.
    • BioMeasurement Division, Hutchinson Technology Inc, 40 West Highland Park Drive NE, Hutchinson, MN 55350-9784, USA. dean.myers@hti.htch.com
    • Crit Care. 2009 Jan 1;13 Suppl 5:S2.

    IntroductionThe tissue hemoglobin index (THI) is a hemoglobin signal strength metric provided on the InSpectra StO2 Tissue Oxygenation Monitor, Model 650. There is growing interest regarding the physiologic meaning of THI and whether a clinically useful correlation between THI and blood hemoglobin concentration exists. A series of in vitro and in vivo experiments was performed to evaluate whether THI has potential utility beyond its primary purpose of helping InSpectra device users optimally position a StO2 sensor over muscle tissue.MethodsThe THI and tissue hemoglobin oxygen saturation (StO2) were measured using the InSpectra StO2 Tissue Oxygenation Monitor, Model 650, with a 15 mm optical sensor. A THI normal reference range was established in the thenar eminence (hand) for 434 nonhospitalized human volunteers. In 30 subjects, the thenar THI was also evaluated during 5-minute arterial and venous blood flow occlusions, and with blood volume exsanguination in the hand induced with an Esmarch bandage. In addition, correlation of the THI to blood total hemoglobin concentration (Hbt) was studied in five pigs whose Hbt was isovolumetrically diluted from 13 to 4 g/dl systemically and 0.5 g/dl locally in the hind limb. The sensitivity and specificity of the THI to measure tissue hemoglobin concentration (THC) were characterized in vitro using isolated blood tissue phantoms.ResultsIn human thenar tissue, the average THI was 14.1 +/- 1.6 (mean +/- standard deviation). The THI extrapolated to 100% blood volume exsanguination was 3.7 +/- 2.0 units presumably from myoglobin. On average, the THI increased 1.5 +/- 1.0 units with venous occlusion and decreased 4.0 +/- 2.0 units with arterial occlusion. In porcine hind limbs, the THI weakly correlated with Hbt (r2 = 0.26) while DeltaTHI during venous occlusion had a stronger correlation (r2 = 0.62). In vitro tests indicated that THI strongly correlated (r2 > 0.99) to phantom THC and was insensitive to StO2 changes.ConclusionsSteady-state THI values do not reliably indicate Hbt. The THI is a reproducible quantitative index for THC, and THI trends can discriminate between arterial or venous blood flow occlusions. The THI magnitude permits the estimation of myoglobin's contribution to StO2.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…