• Eur. Respir. J. · Feb 2006

    Laryngeal ultrasound: a useful method in predicting post-extubation stridor. A pilot study.

    • L-W Ding, H-C Wang, H-D Wu, C-J Chang, and P-C Yang.
    • Dept of Internal Medicine, National Taiwan University Hospital, Chung-Shan South Road, Taipei 100, Taiwan.
    • Eur. Respir. J. 2006 Feb 1;27(2):384-9.

    AbstractThe cuff-leak test was widely used for the prediction of post-extubation stridor, but controversial results limit its clinical application. The current study used real-time ultrasonography to evaluate the air-leak and hypothesised that the air-column width, measured by ultrasonography, may be correlated to the development of post-extubation stridor. From June 1, 2001 to March 1, 2002, a total of 51 planned extubations in 51 consecutively intubated patients were included. All of the patients received ultrasonographical examinations of their vocal cords and larynx in addition to an air-column width measurement within 24 h prior to extubation. The overall post-extubation stridor rate was 7.8%. The air-leak volume presented as median (interquartile range) were 300 (350) mL and 25 (20) mL, respectively, for the nonstridor and stridor groups. The air-column width during cuff deflation was 6.4 (2) mm and 4.5 (0.8) mm, respectively. They were found to be statistically significant. In conclusion, the authors demonstrated that laryngeal ultrasonography could be a reliable, noninvasive method, in the evaluation of vocal cords, laryngeal morphology and the ease of airflow, which passed through vocal cords or subglottic area due to laryngeal oedema. The air-column width during cuff deflation was a potential predictor of post-extubation stridor.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.