Comparative Study
Cementless total hip arthroplasty with large diameter metal-on-metal heads: short-term survivorship of 8059 hips from the Finnish Arthroplasty Register.
- J Mokka, K T Mäkelä, P Virolainen, V Remes, P Pulkkinen, and A Eskelinen.
- Department of Orthopaedics and Traumatology, Surgical Hospital, Turku University Hospital, Turku, Finland.
- Scand J Surg. 2013 Jan 1;102(2):117-23.
Background And AimsPopulation-based register data from the National Joint Register of Australia and England and Wales have revealed that the mid-term outcome of cementless large diameter head metal-on-metal total hip arthroplasty is inferior to that of conventional cemented metal-on-polyethylene total hip arthroplasty. The aim of this study was to compare the results of cementless large diameter head metal-on-metal total hip arthroplasty with conventional cemented arthroplasty in Finland. The second aim of this study was to compare the cementless large diameter head metal-on-metal models with each other.Material And MethodsBased on the data extracted from the Finnish Arthroplasty Register, the risk of revision of 8059 cementless large diameter head metal-on-metal total hip arthroplasties performed during 2002-2009 was analyzed using Cox regression model. The revision risk of these hips was compared to that of 16,978 cemented metal-on-polyethylene total hip arthroplasties performed during the same time period.ResultsIn the Cox regression analysis, there was no difference in revision risks between cementless large diameter head metal-on-metal total hip arthroplasty and cemented metal-on-polyethylene total hip arthroplasty (relative risk = 0.90, confidence interval = 0.74-1.10, p = 0.3). However, in female patients aged 55 years or above, cementless large diameter head metal-on-metal total hip replacements showed a significantly increased risk of revision as compared to cemented total hip replacements (relative risk = 1.33, confidence interval = 1.04-1.70). Compared to the reference implant in this study (cementless Synergy stem combined with Birmingham Hip Resurfacing [BHR] cup), the CementLess Spotorno (CLS) stem combined with Durom cup had a 2.9-fold (95% confidence interval = 1.17-6.90) increased risk of revision.ConclusionsWe found that cementless large diameter head metal-on-metal total hip arthroplasty had short-term survivorship compared with cemented total hip arthroplasty at a nation-wide level. However, in female patients aged 55 years or above, cementless large diameter head metal-on-metal total hip arthroplasty showed inferior results. Furthermore, implant design had an influence on revision rates. Longer follow-up time is needed to assess the success of large diameter head metal-on-metal total hip arthroplasty.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.