Anesthesia and analgesia · Nov 2013
Comparative StudyClosed-Loop Fluid Administration Compared to Anesthesiologist Management for Hemodynamic Optimization and Resuscitation During Surgery: An In Vivo Study.
- Joseph Rinehart, Christine Lee, Cecilia Canales, Allen Kong, Zeev Kain, and Maxime Cannesson.
- From the Departments of *Anesthesiology and Perioperative Care and †Surgery, University of California Irvine, Orange, California.
- Anesth. Analg.. 2013 Nov 1;117(5):1119-29.
BackgroundClosed-loop systems have been designed to assist practitioners in maintaining stability of various physiologic variables in the clinical setting. In this context, we recently performed in silico testing of a novel closed-loop fluid management system that is designed for cardiac output and pulse pressure variation monitoring and optimization. The goal of the present study was to assess the effectiveness of this newly developed system in optimizing hemodynamic variables in an in vivo surgical setting.MethodsSixteen Yorkshire pigs underwent a 2-phase hemorrhage protocol and were resuscitated by either the Learning Intravenous Resuscitator closed-loop system or an anesthesiologist. Median hemodynamic values and variation of hemodynamics were compared between groups.ResultsCardiac index (in liters per minute per square meter) and stroke volume index (in milliliters per square meter) were higher in the closed-loop group compared with the anesthesiologist group over the protocol (3.7 [3.4-4.1] vs 3.5 [3.2-3.9]; 95% Wald confidence interval, -0.5 to -0.23; P < 0.0005 and 40 [34-45] vs 36 [31-38]; 95% Wald confidence interval, -5.9 to -3.1; P < 0.0005, respectively). There was no significant difference in total fluid administration between the closed-loop and anesthesiologist groups (3685 [3230-4418] vs 3253 [2735-3926] mL; 95% confidence interval, -1651 to 431; P = 0.28). Closed-loop group animals also had lower coefficients of variance of cardiac index and stroke volume index during the protocol (11% [10%-16%] vs 22% [18%-23%]; confidence interval, 0.8%-12.3%; P = 0.02 and 11% [8%-16%] vs 17% [13%-21%]; confidence interval, 0.2%-11.4%; P = 0.04, respectively).ConclusionThis in vivo study building on previous simulation work demonstrates that the closed-loop fluid management system used in this experiment can perform fluid resuscitation during mild and severe hemorrhages and is able to maintain high cardiac output and stroke volume while reducing hemodynamic variability.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.