• J Orthop Trauma · Feb 2012

    Infection after spanning external fixation for high-energy tibial plateau fractures: is pin site-plate overlap a problem?

    • Catherine Laible, Emily Earl-Royal, Roy Davidovitch, Mike Walsh, and Kenneth A Egol.
    • Department of Orthopaedic Surgery, NYU Hospital for Joint Diseases, New York, NY, USA.
    • J Orthop Trauma. 2012 Feb 1;26(2):92-7.

    ObjectivesThe purpose of this study was to determine whether overlap between temporary external fixator pins and definitive plate fixation correlates with infection in high-energy tibial plateau fractures.DesignRetrospective chart and radiographic review.SettingAcademic medical center.PatientsSeventy-nine patients with unilateral high-energy tibial plateau fractures formed the basis of this report.InterventionPlacement of knee-spanning external fixation followed by delayed internal fixation for high-energy tibial plateau fractures treated at our institution between 2000 and 2008.MethodsDemographic patient information was reviewed. Radiographs were reviewed to assess for the presence of overlap between the temporary external fixator pins and the definitive plate fixation. Fisher exact and t test analyses were performed to compare those patients who had overlap and those who did not and were used to determine whether this was a factor in the development of a postoperative infection.Main Outcome MeasurementsDevelopment of infection in those whose external fixation pin sites overlapped with the definitive internal fixation device compared with those whose pin sites did not overlap with definitive plate and screws.ResultsSix knees in six patients developed deep infections requiring serial irrigation and débridement and intravenous antibiotics. Of these six infections, three were in patients with closed fractures and three in patients with open fractures. Two of these six infections followed definitive plate fixation that overlapped the external fixator pin sites with an average of 4.2 cm of overlap. In the four patients who developed an infection and had no overlap, the average distance between the tip of the plate to the first external fixator pin was 6.3 cm. There was no correlation seen between infection and distance from pin to plate, pin-plate overlap distance, time in the external fixator, open fracture, classification of fracture, sex of the patient, age of the patient, or healing status of the fracture.ConclusionFears of definitive fracture fixation site contamination from external fixator pins do not appear to be clinically grounded. When needed, we recommend the use of a temporary external fixation construct with pin placement that provides for the best reduction and stability of the fracture, regardless of plans for future surgery.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…