• Anesthesia and analgesia · Jul 1998

    Randomized Controlled Trial Clinical Trial

    Visual evaluation of residual curarization in anesthetized patients using one hundred-hertz, five-second tetanic stimulation at the adductor pollicis muscle.

    • M J Baurain, D A Hennart, A Godschalx, I Huybrechts, G Nasrallah, A A d'Hollander, and F Cantraine.
    • Department of Anesthesiology, University Hospital Erasme, Free University of Brussels, Belgium.
    • Anesth. Analg. 1998 Jul 1;87(1):185-9.

    UnlabelledWe were looking for a clinical test to indicate a train-of-four (TOF) ratio of approximately 0.9. We compared the adductor pollicis muscle (AP) visually evaluated response to ulnar nerve 100-Hz, 5-s tetanus (RF100 Hz) with the measured AP TOF ratio in 30 ASA physical status I or II adult anesthetized (propofol, sufentanil, N2O/O2) patients. After the induction of anesthesia, the left ulnar nerve was stimulated at the wrist (single twitch and TOF) and the resultant isometric force was measured. When TOF was assessed, the independent investigators, unaware of the left AP-measured TOF ratios, visually evaluated the presence or absence of AP fading elicited by right ulnar nerve 100-Hz, 5-s tetanus. The 30 patients were randomly allocated to receive either 0.5 mg/kg atracurium (n = 15) or 0.1 mg/kg vecuronium (n = 15). The neuromuscular blockade was allowed to resolve spontaneously. A multiple logistic regression analysis was performed by computing the 771 visual observations. The probabilities of success of 100-Hz, 5-s tetanus to detect TOF ratios of 0.8, 0.85, and 0.9 were 99%, 96%, and 67%, respectively. The sensitivity and specificity of 100-Hz, 5-s tetanus as an indicator of TOF ratios of 0.85 and 0.9 are 100% and 75%, 54% and 67%, respectively. We conclude that RF100 Hz visual assessment seems to be highly sensitive in evaluating residual paralysis, as the absence of RF100 Hz visual fading at the AP is compatible with a TOF ratio > 0.85.ImplicationsAfter the administration of muscle relaxants, the absence of visual fading at the adductor pollicis, elicited in anesthetized patients by 100-Hz, 5-s tetanus, is compatible with a train-of four ratio > 0.85. Therefore, clinical observation of fading after 100-Hz, 5-s tetanus seems to be a highly sensitive test in evaluating residual paralysis.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…