- A D Bersten, A J Rutten, and A E Vedig.
- Department of Anaesthesia and Intensive Care, Flinders Medical Centre, Adelaide, South Australia.
- Anaesth Intensive Care. 1993 Feb 1;21(1):67-71.
AbstractBreathing through an endotracheal tube, connector, and ventilator demand valve imposes an added load on the respiratory muscles. As respiratory muscle fatigue is thought to be a frequent cause of ventilator dependence, we sought to examine the efficacy of five different ventilators in reducing this imposed work through the application of pressure support ventilation. Using a model of spontaneous breathing, we examined the apparatus work imposed by the Servo 900-C, Puritan Bennett 7200a, Engstrom Erica, Drager EV-A or Hamilton Veolar ventilators, a size 7.0 and 8.0 mm endotracheal tube, and inspiratory flow rates of 40 and 60 l/min. Pressure support of 0, 5, 10, 15, 20 and 30 cm H2O was tested at each experimental condition. Apparatus work was greater with increased inspiratory flow rate and decreased endotracheal tube size, and was lowest for the Servo 900-C and Puritan Bennett 7200a ventilators. Apparatus work fell in a curvilinear fashion when pressure support was applied, with no major difference noted between the five ventilators tested. At an inspiratory flow rate of 40 l/min, a pressure support of 5 and 8 cm H2O compensated for apparatus work through size 8.0 and 7.0 endotracheal tubes and the Servo 900-C and Puritan Bennett 7200a ventilators. However, the maximum negative pressure was greater for the Servo 900-C. The added work of breathing through endotracheal tubes and ventilator demand valves may be compensated for by the application of pressure support. The level of pressure support required depends on inspiratory flow rate, endotracheal tube size, and type of ventilator.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.