-
- Diana M Zuckerman, Paul Brown, and Steven E Nissen.
- National Research Center for Women & Families, Washington, DC 20036, USA. dz@center4research.org
- Arch. Intern. Med. 2011 Jun 13;171(11):1006-11.
BackgroundUnlike prescription drugs, medical devices are reviewed by the US Food and Drug Administration (FDA) using 2 alternative regulatory standards: (1) premarket approval (PMA), which requires clinical testing and inspections; or (2) the 510(k) process, which requires that the device be similar to a device already marketed (predicate device). The second standard is intended for devices that the FDA deems to involve low or moderate risk.MethodsWe analyzed the FDA's high-risk List of Device Recalls from 2005 through 2009. Using FDA data, we determined whether the recalled devices were approved by the more rigorous (PMA) process, the 510(k) process, or were exempt from FDA review.ResultsThere were 113 recalls from 2005 through 2009 that the FDA determined could cause serious health problems or death. Only 21 of the 113 devices had been approved through the PMA process (19%). Eighty were cleared through the 510(k) process (71%), and an additional 8 were exempt from any FDA regulation (7%). Cardiovascular devices comprised the largest recall category, with 35 of the high-risk recalls (31%); two-thirds were cleared by the 510(k) process (66%; n = 23). Fifty-one percent of the high-risk recalls were in 5 other device categories: general hospital, anesthesiology, clinical chemistry, neurology, or ophthalmology.ConclusionsMost medical devices recalled for life-threatening or very serious hazards were originally cleared for market using the less stringent 510(k) process or were considered so low risk that they were exempt from review (78%). These findings suggest that reform of the regulatory process is needed to ensure the safety of medical devices.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.