• J. Cardiothorac. Vasc. Anesth. · Jun 2006

    Cardiac output estimation with a new Doppler device after off-pump coronary artery bypass surgery.

    • Rajesh Chand, Yatin Mehta, and Naresh Trehan.
    • Department of Anesthesiology and Critical Care, Escorts Heart Institute and Research Centre, New Delhi, India.
    • J. Cardiothorac. Vasc. Anesth. 2006 Jun 1;20(3):315-9.

    ObjectiveTo compare cardiac output (CO), stroke volume (SV), and cardiac index (CI) as estimated with a new, noninvasive Doppler device (Ultrasonic Cardiac Output Monitor [USCOM]; USCOM Ltd, Sydney, Australia) with those measured with the bolus thermodilution (TD) technique.DesignProspective nonrandomized study.SettingPostcardiac surgery recovery unit of a tertiary cardiac center.ParticipantsFifty patients after off-pump coronary artery bypass (OPCAB) surgery.Measurement And Main ResultsBoth right-sided and left-sided CO were estimated with a USCOM continuous-wave (CW) Doppler device, and CO was determined with the bolus TD technique performed in triplicate. On comparing the right-sided CO, SV, and CI with those of TD, the mean bias was 0.03 L/min, 1.6 mL, and 0.02 L/min/m(2), respectively. The comparison of left-sided CO, SV, and CI with those of TD revealed a means bias of 0.14 L/min, 1.0 mL, and 0.08 L/min/m(2), respectively.ConclusionThis study showed excellent agreement between the values for CO, SV, and CI as determined with USCOM and TD. Since there was only 1 time period for CO estimation in each patient with both methods, the stability of this correlation needs to be further investigated over time.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.