• Simul Healthc · Jan 2009

    Randomized Controlled Trial

    Improving patient safety with ultrasonography guidance during internal jugular central venous catheter placement by novice practitioners.

    • Sharon Griswold-Theodorson, Hashibul Hannan, Neal Handly, Brian Pugh, John Fojtik, Mark Saks, Richard J Hamilton, and David Wagner.
    • Department of Emergency Medicine, Drexel University College of Medicine, Philadelphia, PA 19102, USA. sgriswol@drexelmed.edu
    • Simul Healthc. 2009 Jan 1;4(4):212-6.

    IntroductionThis study compared ultrasonography-guided (USG) placement with anatomic placement during internal jugular (IJ) central venous catheter (CVC) insertion by novice practitioners using a simulation model.MethodsA prospective, randomized, crossover study of 28 fourth year medical students was conducted with institutional review board approval. Participants viewed an instructional material before participation, and supervision was standardized. Participants were randomly assigned to either USG or traditional landmark method first, and each group served as its own crossover comparison. Paired t tests and χ analysis were performed on matched-pair data.ResultsFifty-four percent of participants had at least one arterial stick without USG compared with 0% when using USG. Significant differences were shown in the USG versus no-USG groups in number of needle advances until successful cannulation of the vein: mean with USG = 1.5 advances (95% CI, 1.0-1.9), mean without USG = 10.4 advances (95% CI, 7.8-13), P < 0.001; time to successful cannulation: mean with USG = 58 seconds (95% CI, 48-72 seconds), mean without USG = 338 seconds (95% CI, 286-390 seconds), P < 0.001; and success rates: 100% with USG and 42.8% without USG (95% CI, 24.5%-61.1%). The number needed to treat to avoid an arterial stick by using USG during IJ insertion by novice practitioners is ∼2.ConclusionsThe USG during IJ CVC placement by novice practitioners is essential to improve patient safety. If these data are extrapolated to impact on patient care, an arterial stick may be avoided in one of every two IJ CVCs placed by novice practitioners. The USG technology should be made available to novice practitioners needing to place CVCs.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.