• J Orthop Trauma · Aug 2005

    Case Reports

    Fixation of transverse fractures of the sternum and sacrum with the locking compression plate system: two case reports.

    • Christoph Sommer.
    • Abteilung für Chirurgie, Kantonsspital Chur, Chur, Switzerland. christoph.sommer@ksc.gr.ch
    • J Orthop Trauma. 2005 Aug 1;19(7):487-90.

    AbstractTransverse fractures of the sternum or sacrum each present specific surgical challenges. Here, we report the successful use of a locking compression plate system in a 69-year-old woman with a displaced segmental fracture of the sternum following a motor vehicle accident and a 15-year-old girl with a low transverse fracture of the sacrum (S3-S4) as a result of a snowboarding accident. In both cases, the system provided adequate fixation to allow healing in the 2 fractures, despite the poor bone quality (sternal case) and the thin bone stock (sacral case).

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.