• Eur J Trauma Emerg S · Jun 2013

    Influence of implant design on the method of failure for three implants designed for use in the treatment of intertrochanteric fractures: the dynamic hip screw (DHS), DHS blade and X-BOLT.

    • F O'Neill, T McGloughlin, B Lenehan, F Condon, J C Coffey, and M Walsh.
    • Centre for Applied Biomedical Engineering Research (CABER), Department of Mechanical and Aeronautical Engineering and Materials and Surface Science Institute (MSSI), University of Limerick, Co. Limerick, Ireland. fneill09@yahoo.com.
    • Eur J Trauma Emerg S. 2013 Jun 1;39(3):249-55.

    BackgroundThe dynamic hip screw (DHS) has been widely adopted as the implant of choice in the treatment of intertrochanteric fractures. There have been attempts over the years to improve on the DHS lag screw design in order to reduce failure in the form of "cut out". The purpose of this study was to investigate how two new design variations of the DHS, the DHS blade and the X-BOLT, behave within bone, and if these design modifications do indeed improve the fixation achieved and lead to a reduction in failure due to cut out.Methods"Pushout" tests were chosen as the means of investigating the failure modes and patterns for these implants that lead to cut out. These pushout studies were performed in artificial bone substrate in the form of polyurethane foam blocks and in cadaveric femoral heads.ResultsThe results demonstrated that each individual implant produces its own specific distinct force-displacement curve or pattern of failure, and that despite the very different implant designs and methods of fixation, all of the implants tested reached very similar peak forces in each of the test materials used.ConclusionThe results demonstrated that implant design only influences the pattern of failure, and that the peak forces reached by each implant are determined by the quality of the bone or test material into which they are placed. However, altering the force-displacement curve or pattern of failure may be enough to improve the fixation achieved and to provide an increased resistance to cut out.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.