-
Randomized Controlled Trial Multicenter Study Clinical Trial
Treatment of complex tibial plateau fractures using the less invasive stabilization system plate: clinical experience and a laboratory comparison with double plating.
- Kenneth A Egol, Edward Su, Nirmal C Tejwani, Stephen H Sims, Frederick J Kummer, and Kenneth J Koval.
- Department of Orthopaedic Surgery, NYU-Hospital for Joint Diseases, New York, New York, USA.
- J Trauma. 2004 Aug 1;57(2):340-6.
BackgroundBicondylar tibial plateau fractures are complex injuries, historically associated with high complication rates. The purpose of this study was: 1) to evaluate the clinical use L.I.S.S plating system for stabilization of bicondylar tibial plateau fractures. 2) To compare the biomechanics of this plating system with a double plate construct.Methods And MaterialsThirty-eight patients who sustained a complex tibial plateau fracture (OTA type 41C) at one of three level-one trauma centers were stabilized using the Less Invasive Stabilization System (L.I.S.S.). The cohort of patients was evaluated clinically and radiographically for outcomes at a mean 15 months. In phase 2 of this study a model of a bicondylar tibial plateau fractures was made in six matched pairs of embalmed, human tibia and randomized to fixation with either a L.I.S.S plate or a standard double plate construct. The tibias were then subjected to an axial cyclic load of 500N for 10 cycles (3Hz) to approximate 2 months in vivo and displacements measured.ResultsThirty-six of /38 (95%) patients united at 4 months after surgery with no loss of fixation nor infection. Two patients underwent prophylactic autogenous bone grafting for bone loss and united by 3 months postgrafting. Significant loss of knee range of motion (<90) was seen in five patients.Biomechanically, no differences in permanent inferior displacement of the medial fragment were found in initial axial loading and after 10 cycles between the two plate constructs. However, when loaded to 500N the L.I.S.S plate construct demonstrated almost twice the displacement of the medial fragment compared with the dual plate construct. No specimen lost fixation during cycling.ConclusionThe L.I.S.S plating system provides stable fixation of complex bicondylar tibial plateau fractures allowing early range of knee motion with favorable clinical results.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.