• Radiology · Feb 2005

    Comparative Study

    Chronic obstructive pulmonary disease: thin-section CT measurement of airway wall thickness and lung attenuation.

    • Ilaria Orlandi, Chiara Moroni, Gianna Camiciottoli, Maurizio Bartolucci, Massimo Pistolesi, Natale Villari, and Mario Mascalchi.
    • Radiodiagnostic Section, Department of Clinical Physiopathology, University of Florence, Viale Morgagni 85, Florence 50134, Italy.
    • Radiology. 2005 Feb 1;234(2):604-10.

    PurposeTo prospectively evaluate airway wall thickness and lung attenuation at spirometrically gated thin-section computed tomography (CT) in patients with chronic obstructive pulmonary disease (COPD) and to correlate gated CT findings with pulmonary function test (PFT) results.Materials And MethodsThe ethical committee approved the study, and all patients gave informed consent. Forty-two consecutive patients with COPD (20 with and 22 without chronic bronchitis [CB]) underwent gated thin-section CT and PFTs on the same day. The percentage wall area (PWA) and the thickness-to-diameter ratio (TDR) for all depicted bronchi that were round and larger than 2 mm in diameter, the mean lung attenuation (MLA), and the pixel index (PI) at -950 HU were determined. The reproducibility of the airway measurements was preliminarily tested by performing a five-trial examination in a patient with COPD and in a control patient. Differences in airway and lung attenuation measurements between the patients with and those without CB were evaluated at Mann-Whitney U testing. Simple and multiple regression analyses were used to assess the correlation between thin-section CT and PFT measurements.ResultsThe mean intraoperator coefficient of variation for airway measurements was 7.8% (range, 3.8%-13.4%). An average of nine bronchi per patient were assessed. Patients with CB had significantly higher PWAs, TDRs, and MLAs and significantly lower PIs than patients without CB (P < .05 for all values). The combination of PWA, TDR, and PWA normalized to body weight correlated significantly (P < .05) with the forced expiratory volume in 1 second-to-slow vital capacity ratio and the diffusing capacity of the lung for carbon monoxide in patients with but not in patients without CB. PFT results correlated better with MLA and PI in patients without CB.ConclusionBronchial wall measurements differ between patients who have COPD with CB and those who have COPD without CB. The correlation between airway dimensions and indexes of airway obstruction in patients with COPD and CB indicates that the bronchial tree is the site of anatomic-functional alterations in this patient group.(c) RSNA, 2005.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.