    [Analysis of implantation-induced nail deformation and roentgen morphometric studies as the principle for an aiming device for distal interlocking nailing without roentgen image intensification].

    • C Krettek, B Könemann, J Mannss, P Schandelmaier, U Schmidt, and H Tscherne.
    • Unfallchirurgische Klinik, Medizinische Hochschule Hannover.
    • Unfallchirurg. 1996 Sep 1;99(9):671-8.

    AbstractWhile working to develop a distal locking device, we analyzed distal nail position with reference to nail deformation and a radiographic-morphometric investigation. The amount and the direction of implant deformation in unslotted stainless steel unreamed tibial nails (Synthes) were analyzed. Measurement of implant deformation (3 translations, 3 angles) in the center of the distal transverse locking hole was performed with a 3D magnetic motion tracker system before and after nail insertion. Unreamed tibial nails (diameter 8 mm, n = 10; diameter 9 mm, n = 10) were inserted in paired human cadaver tibiae. The results showed lateral translations of -4.5 +/- 3.5 mm (mean and standard deviation, range 14.3 mm) and dorsal translations of -7.8 +/- 5.8 mm (mean and standard deviation, range 19.2 mm). Rotational deformations around the longitudinal axis of the nail were 0.3 +/- 0.7 degree (mean and standard deviation, range 2.4 degrees). The results showed, that a simple aiming arm, mounted on the proximal nail end, alone or even in combination with a large working channel (e.g. 10 mm in diameter), was not adequate to the aiming process. A radiographic-morphometric analysis was subsequently performed in 40 tibiae after experimental (n = 20) or clinical (n = 20) implantation of nails 8 mm and 9 mm in diameter. These measurements showed a relatively constant distance between the upper distal transverse hole and the anterior aspect of the tibia (average 12.3 mm and only a narrow range (7.6 mm). These data were the basis for the development of an aiming technique that exploits the relatively constant distance between the distal nail hole and the anterior aspect of the tibia. This aiming device is set at a distance of 12.3 mm from the anterior cortex, and the fine tuning is finally resolved by the use of a "working channel' 10 mm in diameter.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.