• J Cardiovasc Med (Hagerstown) · Nov 2011

    Comparative Study

    Comparison of invasive and non-invasive measurements of haemodynamic parameters in patients with advanced heart failure.

    • Mateusz Sokolski, Agnieszka Rydlewska, Bartosz Krakowiak, Jan Biegus, Robert Zymlinski, Waldemar Banasiak, Ewa Anita Jankowska, and Piotr Ponikowski.
    • Department of Heart Diseases, Wroclaw Medical University, Wroclaw, Poland. matsok@gmail.com
    • J Cardiovasc Med (Hagerstown). 2011 Nov 1;12(11):773-8.

    AimMeasurement of haemodynamic parameters using a Swan-Ganz catheter is of clinical importance in patients with advanced heart failure; however, its applicability is limited due to its invasiveness. The aim of the study was to estimate the concordance between invasive and non-invasive measurements of haemodynamic parameters in patients with advanced heart failure.Methods And ResultsWe examined 25 patients with advanced heart failure (20 men, age: 64 ± 11 years, New York Heart Association class III/IV: 88/12%, left ventricular ejection fraction: 37 ± 20%), 13 (52%) demonstrated decompensated heart failure. Resting haemodynamic parameters were measured simultaneously using two methods: an invasive Swan-Ganz catheterization and a thermodilution technique; and a non-invasive recording using a device for finger arterial pressure waveform analysis. The following parameters were analysed: stroke volume (SV, ml), cardiac output (CO, l/min) and systemic vascular resistance (SVR, dyne × s/cm⁵). The concordance between these two methods was assessed using the variability coefficient calculated according to a Bland-Altman method. Comparing the invasive and non-invasive measures, variability coefficients were: 13, 18 and 11% for SV, SVR and CO, respectively. Similar variability coefficients were obtained when invasive and non-invasive measurements were compared in prespecified subgroups of patients, distinguished based on the presence of decompensation, atrial fibrillation and values of SBP.ConclusionsEvaluation of haemodynamic parameters using a non-invasive method based on a pressure pulse contour model reveals an adequate concordance with the measures obtained using an invasive approach. Our results suggest that a non-invasive method for haemodynamic monitoring could be applied in clinical practice in patients with advanced heart failure.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.