    A Novel Combined-Catheter to Monitor Left and Right Atrial Pressures: A Simple and Reliable Method for Pediatric Cardiac Surgery.

    • Jie Ding, Quanyi Zhang, Lihuan Li, Hao Zhang, Jun Yan, Shoujun Li, and Fuxia Yan.
    • 1Department of Anesthesiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China. 2Department of Surgery and Center for Pediatric Cardiac Surgery, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
    • Pediatr Crit Care Me. 2016 Mar 1; 17 (3): 210-5.

    ObjectiveTo introduce a novel combined-catheter to monitor left and right atrial pressures.DesignProspective observational study.SettingFuwai Hospital, China.PatientsA total of 113 pediatric patients (77 men), median age 10.3 months, admitted between July 10, 2014, and February 5, 2015, were divided into two groups: the novel-catheter group and the traditional-method group.InterventionsAll patients received routine anesthesia and surgery. Left atrial pressure and central venous pressure (an estimate of right atrial pressure), measured through a catheter needle during surgery, were identified as the "gold standard." A novel combined-catheter, composed of a reformed triple-lumen catheter with a microtube inserted within its central cavity, was used in the novel-catheter group. A traditional triple-lumen catheter to monitor central venous pressure plus another single-lumen catheter to monitor left atrial pressure were used in the traditional-method group.Measurements And Main ResultsThe novel combined-catheter could accurately monitor left atrial pressure and central venous pressure. Pressure values measured by the novel catheter correlated well with the gold standard (left atrial pressure, R = 0.98; central venous pressure, R = 0.99). Bland-Altman analyses revealed good agreement between pressures measured by the novel catheter and the gold standard. The absolute value of maximum difference was 0.67 mm Hg for left atrial pressure and 0.33 mm Hg for central venous pressure, which are acceptable in clinical practice. Left atrial pressure-monitoring catheter displaced into the right atrium occurred significantly less frequently in the novel-catheter group when compared with the traditional-method group (5 and 12 cases, respectively).ConclusionsThis novel combined-catheter was safe and reliable at monitoring left and right atrial pressures, and infusion involved only one catheter without the disadvantages of the traditional method. This new novel method may be particularly useful in pediatric open-heart surgery.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…