-
Randomized Controlled Trial Comparative Study Clinical Trial
[Comparison of volume preset and pressure preset ventilators during daytime nasal ventilation in chronic respiratory failure].
- C Perrin, P Wolter, F Berthier, R Tamisier, V Jullien, F Lemoigne, and B Blaive.
- Service de Pneumologie et Réanimation Respiratoire, Centre Hospitalier et Universitaire de Nice, France.
- Rev Mal Respir. 2001 Feb 1;18(1):41-8.
AbstractBoth volume preset and pressure preset ventilators are available for domiciliary nasal ventilation. Owing to their technical characteristics, it has been suggested that impaired ventilatory mechanics might cause a drop in the tidal volume (Vt) delivered by pressure preset devices, thereby placing mechanical ventilation at risk of inefficacy. We have assessed two ventilator systems (one pressure preset and one volume preset) with regard to the tidal volume and end-tidal carbon dioxide tension (PetCO(2)) changes that may be achieved in a group of awake patients with stable chronic respiratory failure (CRF). Eleven patients with stable CRF were ventilated in the assist/control mode for two consecutive one-hour periods. One ventilator was tested each hour, in random order. The VIGIL'AIR(R) system was used to record Vt, Respiratory Rate (RR), and Inspiratory/Expiratory ratio (I/E). The deviation E (E=preset value - measured value) was calculated for each measurement. Changes in PetCO(2) and arterial oxygen saturation were determined respectively by a capnometer and a pulse oximeter. Comparison of the mean deviation of Vt calculated for the two ventilators revealed a difference in patients with chronic obstructive pulmonary disease (COPD). The deviation was greatest with the pressure preset ventilator (PPV), which gave mean measured values higher than the mean preset values. The same comparison failed to reveal any difference in restrictive CRF. Comparison of the volume preset and pressure preset ventilators for RR, I/E and PetCO(2) did not reveal any difference. Compared to the volume preset ventilator, the efficacy of PPV to ventilate is not affected by the restrictive or obstructive nature of CRF. Our results show that pressure-preset ventilator is an adequate alternative to the volume-preset device for daytime non invasive ventilation in chronic respiratory insufficiency.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.