• Radiology · Aug 2005

    Comparative Study

    Middle cerebral artery spasm after subarachnoid hemorrhage: detection with transcranial color-coded duplex US.

    • Jaroslaw Krejza, Jan Kochanowicz, Zenon Mariak, Janusz Lewko, and Elias R Melhem.
    • Department of Radiology, University of Pennsylvania, Science Building, Suite 370, 3600 Market St, Philadelphia, PA 19104, USA. Jaroslaw.Krejza@uphs.upenn.edu
    • Radiology. 2005 Aug 1;236(2):621-9.

    PurposeTo prospectively determine the accuracy of transcranial color-coded duplex ultrasonography (US) used alone and in conjunction with carotid artery US for diagnosis of middle cerebral artery (MCA) spasm, with intraarterial digital subtraction angiography (DSA) used as the reference standard.Materials And MethodsThe institutional ethics committee approved the study. Each patient, or members of the patient's family, gave informed consent. One hundred twenty consecutive patients (64 women, 56 men; mean age, 45.5 years +/- 13.6 [standard deviation]) were routinely referred for DSA after subarachnoid hemorrhage. Vasospasm was graded as mild (< or =25% reduction in vessel diameter), moderate (>25% to 50% reduction), or severe (>50% reduction). US was performed 2 hours or less before angiography. The ratio of flow velocity in the middle cerebral artery (V(MCA)) to flow velocity in the ipsilateral extracranial internal carotid artery (V(ICA)) was calculated. Diagnostic accuracy was evaluated by calculating the area under the receiver operating characteristic curve (Az). The significance of the difference between the two Az values (for US vs DSA) was determined by using the z test with correction for correlated data.ResultsNine of 120 patients were excluded because of inadequacy of acoustic windows in the squama of temporal bones. Spasm was mild in 17, moderate in 16, and severe in only nine of 222 arteries studied. Arteries with moderate or severe vasospasm were combined in one group. The best-performing parameters were peak systolic velocity and V(MCA)/V(ICA) ratio. Az values for these two parameters in diagnosis of moderate-to-severe vasospasm were 0.93 and 0.95, and in diagnosis of mild vasospasm, 0.90 and 0.91. Accuracy of the V(MCA)/V(ICA) ratio calculated on the basis of end-diastolic velocity for diagnosis of mild MCA narrowing was significantly better than that of end-diastolic MCA velocity alone (Az = 0.88 vs 0.84, P < .05). The stepwise approach with use of the V(MCA)/V(ICA) ratio after flow velocity measurements in the MCA resulted in a decreased number of false-negative findings in both vasospasm subgroups. The thresholds of highest efficiency were at a mean velocity of 94 and 108 cm/sec and a peak systolic V(MCA)/V(ICA) ratio of 3.6 and 3.9 for diagnosis of mild and moderate-to-severe vasospasm, respectively.ConclusionTranscranial color-coded duplex US alone or in conjunction with carotid artery US has excellent accuracy for angiographic detection of vasospasm. Use of MCA velocity measurements and V(MCA)/V(ICA) ratio can increase the accuracy of Doppler US.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.