-
Randomized Controlled Trial
Artificial acrylic finger nails may alter pulse oximetry measurement.
- Jochen Hinkelbein, Heike Koehler, Harald V Genzwuerker, and Fritz Fiedler.
- University Clinic for Anaesthesiology and Intensive Care Medicine, Medical Faculty Mannheim, Ruprecht-Karls-University Heidelberg, University Hospital Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany. jochen.hinkelbein@anaes.ma.uni-heidelberg.de
- Resuscitation. 2007 Jul 1;74(1):75-82.
IntroductionPulse oximetry is the most common technique to monitor oxygen saturation (SpO(2)) during intensive care therapy. However, intermittent co-oximetry is still the "gold standard" (SaO(2)). Besides acrylic nails, numerous other factors have been reported to interfere with pulse oximetry. Data of measurements with artificial finger nails are not sufficiently published.Materials And MethodsA prospective clinical-experimental trial in mechanically ventilated and critically ill patients of an ICU was performed. Patients were randomly assigned to either group S (S: Siemens pulse oximeter) or group P (P: Philips pulse oximeter) prior to the measurements. SpO(2) was determined in each patient three times alternately in standard ((N)SpO(2)) and sideways position at the natural nail ((N90)SpO(2)). For the reference measurements oxygen saturation was measured by means of a haemoximeter (co-oximetry). Thereafter, SpO(2) was obtained at the acrylic finger nail in the same way ((A)SpO(2) and (A90)SpO(2)). Bias was calculated as DeltaS=(N)SpO(2)-SaO(2) and DeltaS=(A)SpO(2)-SaO(2). Accuracy (mean difference) and precision (standard deviation) were used to determine the measurement discrepancy. P<0.05 was considered significant.ResultsAccuracy and precision without acrylic nails applied were comparable to SaO(2) in both groups (n.s.). With acrylic nails applied a bias of DeltaS=-1.1+/-3.14% for group S (P=0.00522) and a bias of DeltaS=+0.8+/-3.04% for group P was calculated (n.s.).ConclusionAcrylic finger nails may impair the measurement of oxygen saturation depending on the pulse oximeter used and may cause significant inaccuracy. Hence, removal of artificial acrylic finger nails may be helpful to assure an accurate and precise measurement with pulse oximetry.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.