• Neurological research · Apr 1995

    Noninvasive cerebral optical spectroscopy: depth-resolved measurements of cerebral haemodynamics using indocyanine green.

    • K Hongo, S Kobayashi, H Okudera, M Hokama, and F Nakagawa.
    • Department of Neurosurgery, Shinshu University School of Medicine, Matsumoto, Japan.
    • Neurol. Res. 1995 Apr 1;17(2):89-93.

    AbstractTo investigate the feasibility of a newly developed, near-infrared optical spectroscopy device, we analysed measurements of the infrared tracer indocyanine green (ICG) using sensors with a single near infrared light source and multiple light detectors. Two ml of ICG dye, 1.0 mg ml-1 in concentration, were injected into the internal carotid artery during cerebral angiography in 14 adult patients. The resultant washout curves were measured bilaterally using sensors with 4 detectors spaced at 10, 20, 30 and 40 mm from the infrared light source on the right side, and 15, 25, 35 and 45 mm from the source for the left side, respectively. Washout curves were analysed to determine the relative amplitude of the ICG absorption signal and deduce each detector's penetration distance. When ICG was injected into the internal carotid artery, relative absorption increased with detector distance from the light source. No substantial difference in attenuation was observed in any of the detectors during external carotid injection of ICG. The resultant information related depth of penetration of the light with source-detector separation distances. The feasibility of the system for measuring cerebral oxygen saturation and haemodynamics noninvasively or monitoring at bedside is discussed.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…