- Kathryn Roberts, Vijay Srinivasan, Dana E Niles, Joar Eilevstjønn, Lisa Tyler, Lori Boyle, Ram Bishnoi, Susan Ferry, Jon Nysaether, Mette Stavland, Ronald S Litman, Mark Helfaer, and Vinay Nadkarni.
- Department of Nursing, The Children's Hospital of Philadelphia, Philadelphia, PA 19104, USA.
- Resuscitation. 2010 Nov 1;81(11):1544-9.
IntroductionResuscitation guidelines recommend rescue ventilations consist of tidal volumes 7-10 ml/kg. Changes in thoracic impedance (ΔTI) measured using defibrillator electrode pads to detect and guide rescue ventilations have not been studied in children.AimWe hypothesized that ΔTI measured via standard anterior-apical (AA) position can accurately detect ventilations with volume > 7 ml/kg in children. We also compared standard AA position with alternative anterior-posterior (AP) position.MethodsIRB-approved, prospective, observational study of sedated, subjects (6 months to 17 years) on conventional mechanical ventilation. Thoracic impedance (TI) was obtained via Philips MRx defibrillator with standard electrode pads for 5 min each in AA and AP positions. Ventilations were simultaneously measured by pneumotachometer (Novametrix CO(2)SMO Plus).ResultsTwenty-eight subjects (median 4 years, IQR 1.7-9 years; median 16.3 kg, IQR 10.5-39 kg) were enrolled. Data were available for 21 episodes in AA position and 22 episodes in AP position, with paired AA and AP data available for 18. For ventilations with volume < 7 ml/kg, the defibrillator algorithm detected 80.0% for both AA and AP (p=0.99). For ventilations ≥ 7 ml/kg, detection was 95.1% for AA and 95.7% for AP (p=0.38).ConclusionsChanges in thoracic impedance obtained via defibrillator pads can accurately detect ventilations above 7 ml/kg in stable, mechanically ventilated children, corresponding to rescue ventilations recommended during CPR. Both AA and AP pad positions were less sensitive to detect smaller volumes (< 7 ml/kg) than higher volumes (≥ 7 ml/kg), suggesting that shallow ventilations during CPR might be missed. There were no differences in impedance measurements between standard AA pad position and commonly used alternative AP pad position.Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.