• Pharmacotherapy · Oct 2005

    Low-molecular-weight heparin may alter point-of-care assay for international normalized ratio.

    • Elizabeth M Phillips, Debra A Buchan, Nancy Newman, Arun Rajan, and Shams Zia.
    • Department of Medicine, State University of New York Upstate Medical University, Syracuse, New York, USA.
    • Pharmacotherapy. 2005 Oct 1;25(10):1341-7.

    Study ObjectiveTo compare the international normalized ratio (INR) measured by a point-of-care testing device with that measured by a reference laboratory method for patients receiving either warfarin only or warfarin plus low-molecular-weight heparin (LMWH).DesignRetrospective study.SettingOutpatient anticoagulation clinic.SubjectsNinety-one patients receiving warfarin for various indications; 59 of them receiving only warfarin and 32 receiving warfarin plus LMWH.InterventionCapillary blood was obtained for INR determination by a point-of-care device, and venous blood was obtained for INR determination in a standard reference laboratory.Measurements And Main ResultsNinety-one patients had INR pairs run on a point-of-care device and by the laboratory. In both the patients receiving only warfarin and in those receiving warfarin plus LMWH, the mean INR as determined by the point-of-care testing device was statistically significantly higher than the mean INR determined by the laboratory. Although the differences were statistically significant in both groups, the clinical significance of this difference was accentuated in the patients receiving warfarin plus LMWH. The measure of divergence between the point-of-care and laboratory methods was greater in the group receiving warfarin plus LMWH than in the warfarin-only group, with a mean +/- SD percent change between the INR values of 24.19 +/- 27.54% in the warfarin plus LMWH group and 7.21 +/- 17.73% in the warfarin-only group. In assessing the clinical impact of such variability, a greater degree of discordance in dosing adjustment decisions was noted for patients receiving warfarin plus LMWH. In this group, a 25% rate of discordance was noted compared with 8% in the warfarin-only group. Such discrepancy in dosing decisions based on the point-of-care INR would have resulted in discontinuation of LMWH therapy before the patient acquired a true therapeutic INR, with use of the laboratory measurement.ConclusionThe INR measured with the point-of-care device in patients receiving concurrent LMWH and warfarin therapy may be inaccurate. Patients receiving LMWH in addition to warfarin should have INRs checked by means of the standard reference laboratory method.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…