• Rev Esp Anestesiol Reanim · Feb 1996

    Comparative Study

    [Comparison of 2 systems for continuous intraoperative monitoring of oxygen saturation in the jugular bulb].

    • S García del Valle, A Bartolomé, B Menéndez, J Azofra, and M D Requejo.
    • Servicio de Anestesiología y Reanimación, Hospital Puerta de Hierro, Madrid.
    • Rev Esp Anestesiol Reanim. 1996 Feb 1;43(2):49-52.

    ObjectiveTo compare accuracy, precision and stability of two jugular venous blood catheters for continuous monitoring of oxygen saturation during surgery, in a nonrandom, prospective sample.Patients And MethodsWe studied 47 patients requiring continuous monitoring of SjvO2 during a variety of neurosurgical procedures. Swan-Ganz pediatric 5.5F catheters (Opticath P575-EH) were used in 27 patients; neonatal umbilical artery 4F catheters (Opticath U425C) were used in 20. Both catheters were equipped with a fiberoptic system for continuous monitoring of hemoglobin oxygen saturation. After checking correct placement, readings transmitted were compared with co-oximetry readings for a sample taken from the distal end of the catheter. We also compared time spent placing the catheters and stability of SjvO2 reading during surgery.ResultsInsertion time (+/- SD) was 10.3 +/- 2.5 minutes for the 4F catheter and 15.9 +/- 5.5 minutes for the 5.5F model (p < 0.01). Although both systems tended to overestimate, the 5.5F catheters were more accurate: the mean differences were -6.8% for the 4F catheter and -1.2% for the 5.5F. These results made it necessary to calibrate the 4F catheters after placement and before use, a procedure not needed if the 5.5F catheters are used. Stability of SjvO2 readings during surgery was significantly greater (p < 0.01) for the 5.5F catheters, such that only 25.9% were considered clinically useful based on this parameter. However, 70% of the 5.5F catheters provided acceptable SjvO2 readings. Intracranial pressure during insertion and removal of the SjvO2 catheters was measured in only 5 patients; there were no changes greater than 1 mmHg.ConclusionsAlthough the 5.5F pediatric catheters take longer to put into position, their greater accuracy, precision and stability makes them preferable to the 4F catheters for continuous monitoring of SjvO2. Long-term vascular effects must be studied further.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.