Observational Study
Robotic assisted prostatic surgery in the Trendelenburg position does not impair cerebral oxygenation measured using two different monitors: A clinical observational study.
- Dorothea Closhen, Adrian-Hennig Treiber, Manfred Berres, Anne Sebastiani, Christian Werner, Kristin Engelhard, and Patrick Schramm.
- From the Department of Anaesthesiology (DC, A-HT, AS, CW, KE, PS); Institute of Medical Biometry, Epidemiology and Informatics (IMBEI), University Medical Centre of the Johannes Gutenberg-University Mainz, Mainz (MB); Department of Mathematics and Technology, RheinAhrCampus, Remagen, Germany (MB).
- Eur J Anaesthesiol. 2014 Feb 1; 31 (2): 104-9.
BackgroundRobotic assisted prostatic surgery is frequently used because of its reduced side-effects compared with conventional surgery. During surgery, an extreme Trendelenburg position and CO2 pneumoperitoneum are necessary, which may lead to cerebral oedema, can potentially reduce brain perfusion and therefore could impair cerebral oxygenation. Cerebral oxygen saturation can be measured non-invasively using near-infrared spectroscopy (NIRS).ObjectiveThe hypothesis of the present study was that steep Trendelenburg positioning during robotic assisted prostatic surgery impairs cerebral oxygen saturation measured using two different NIRS monitors.DesignClinical observational study.SettingPrimary care university hospital, study period from March 2012 to February 2013.PatientsA total of 29 patients scheduled for robotic assisted prostatic surgery in a steep Trendelenburg position.InterventionsCerebral oxygen saturation was measured throughout anaesthesia using the INVOS sensor (a trend monitor using two infrared wavelengths) for one hemisphere and the FORE-SIGHT sensor (a monitor using four wavelengths of laser light to calculate absolute oxygen saturation) for the other hemisphere in an alternate randomisation.Main Outcome MeasureChanges in cerebral oxygenation of more than 5% during surgery in the Trendelenburg position.ResultsThe median duration of Trendelenburg positioning was 190 (interquartile range 130 to 230) min. Cerebral oxygen saturation decreased with INVOS from 74 ± 5% at baseline to a lowest value of 70 ± 4% with a slope of -0.0129 min(-1) (P < 0.01) and with FORE-SIGHT from 72 ± 5% at baseline to a nadir of 70 ± 3% with a slope of -0.008 min(-1) (P < 0.01). Comparing INVOS with FORE-SIGHT, there was a good association, with a slope of 0.86 ± 0.04 (P < 0.01).ConclusionBoth monitors showed a clinically irrelevant decrease in cerebral oxygen saturation of less than 5% over 4 h in a steep Trendelenburg position combined with CO2 pneumoperitoneum in patients undergoing robotic assisted prostatic surgery. This extreme positioning seems to be acceptable with regard to cerebral oxygenation.Trial Registrationclinicaltrials.gov Identifier: ID NCT01275898.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.