- D I Sessler and A Moayeri.
- Department of Anesthesia, University of California, San Francisco 94143-0648.
- Anesthesiology. 1990 Aug 1;73(2):218-24.
AbstractThe authors determined the efficacy of four postoperative warming devices by measuring cutaneous and tympanic membrane temperatures, and heat loss/gain using 11 thermocouples and ten thermal flux transducers in five healthy, unanesthetized volunteers. Overall thermal comfort was evaluated at 5-10 min intervals using a 10-cm visual analog scale. The warming devices were: 1) a pair of 250-W infrared heating lamps mounted 71 cm above the abdomen; 2) the Thermal Ceiling MTC XI UL (500 W) set on "high" and mounted 56 cm above the volunteer; 3) a 54-by-145-cm circulating-water blanket set to 40 degrees C placed over the volunteer; and 4) the Bair Hugger forced air warmer with an adult-sized cover set on "low" (approximately 33 degrees C), "medium" (approximately 38 degrees C), and "high" (approximately 43 degrees C). Following a 10-min control period, each device was placed over the volunteer and activated for a 30-min period. All devices were started "cold" and warmed up during the study period. The Bair Hugger set on "medium" decreased heat loss more than each radiant warming device and as much as the circulating-water blanket. All methods reached maximum efficacy within 20 min. Set on "high," the Bair Hugger increased skin-surface temperature more than the circulating-water blanket. The Bair Hugger (all settings) and the water blanket raised skin temperature more than the radiant heaters. The circulating-water blanket was the most effective device for heating an optimally placed transducer on the chest (directly under and parallel to the radiant heat sources, and touching the water and Bair Hugger blankets).(ABSTRACT TRUNCATED AT 250 WORDS)
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.