-
Comparative Study
Evaluation of NuStat?, a Novel Nonimpregnated Hemostatic Dressing, Compared With Combat Gauze in Severe Traumatic Porcine Hemorrhage Model.
- Genevieve R Hillis, Crystal J Yi, David L Amrani, Troy W Akers, Richard Schwartz, Ian Wedmore, and John G McManus.
- J Spec Oper Med. 2014 Jan 1; 14 (4): 41-7.
BackgroundUncontrolled hemorrhage remains one of the most challenging problems facing emergency medical professionals and a leading cause of traumatic death in both battlefield and civilian environments. Survival is determined by the ability to rapidly control hemorrhage. Several commercially available topical adjunct agents have been shown to be effective in controlling hemorrhage, and one, Combat Gauze (CG), is used regularly on the battlefield and for civilian applications. However, recent literature reviews have concluded that no ideal topical agent exists for all injuries and scenarios. The authors compared a novel nonimpregnated dressing composed of cellulose and silica, NuStat (NS), to CG in a lethal hemorrhagic groin injury. These dressings were selected for their commercial availability and design intended for control of massive hemorrhage.MethodsA complex penetrating femoral artery groin injury was made using a 5.5mm vascular punch followed by 45 seconds of uncontrolled hemorrhage in 15 swine. The hemostatic dressings were randomized using a random sequence generator and then assigned to the animals. Three minutes of manual pressure was applied with each agent after the free bleed. Hextend bolus (500 mL) was subsequently rapidly infused using a standard pressure bag along with the addition of maintenance fluids to maintain blood pressure. Hemodynamic parameters were recorded every 10 minutes and additionally at critical time points defined in the protocol. Primary end points included immediate hemostasis upon release of manual pressure (T0), hemostasis at 60 minutes, and rebleeding during the 60-minute observation period.ResultsNS was statistically superior to CG in a 5.5 mm traumatic hemorrhage model at T0 for immediate hemostasis (p=.0475), duration of application time (p=.0093), use of resuscitative fluids (p=.0042) and additional blood loss after application (p=.0385). NS and CG were statistically equivalent for hemostasis at 60 minutes, rebleeding during the study, and the additional secondary metrics, although the trend indicated that in a larger sample size, NS could prove statistical superiority in selected categories.ConclusionsIn this porcine model of uncontrolled hemorrhage, NS improved immediate hemorrhage control, stability, and use of fluid in a 60-minute severe porcine hemorrhage model. In this study, NS demonstrated equivalence to CG at achieving long-term hemostasis and the prevention of rebleed after application. NS was shown to be an efficacious choice for hemorrhage control in combat and civilian emergency medical service environments.2014.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.