• Gastrointest. Endosc. · Oct 2006

    Three-dimensional US volume analysis of gastric pseudotumors in a porcine model.

    • Anil Vegesna, Rina Raju, Wassim Asfari, Annapurna Korimilli, Apurva Varia, Nicholas Orfanidis, John Gaughan, Zeeshan Ramzan, and Larry S Miller.
    • Department of Gastroenterology, Temple University Hospital, Philadelphia, Pennsylvania 19040, USA.
    • Gastrointest. Endosc. 2006 Oct 1;64(4):635-40.

    BackgroundTumor burden is difficult to estimate by endoscopy and conventional EUS.ObjectiveThe purpose of this study was to determine the accuracy and the reliability of a new 3-dimensional (3D) EUS system in a pseudotumor model (Olympus EUS EXERA EU-M60).DesignA pseudotumor model was developed in a porcine stomach. Pseudotumors were created by injecting various volumes of US gel (0.3, 0.5, 0.7, and 1 mL) into porcine stomach specimens, and then the volume was measured in vitro. Two investigators made volume measurements by outlining the cross-sectional area of the pseudotumor at different radial planes. The instrument then automatically calculated the volume based on the outlined cross-sectional areas. The measured volume was compared with the actual volume of the pseudotumor by using a Bland-Altman analysis. Every second, third, fourth, fifth, sixth, and tenth image was measured to calculate the tumor volume and to determine the optimum number of images required for accurate volume determination. Inter- and intraobserver variability, percentage error, Bland-Altman analysis, analysis of variance (ANOVA), and kappa statistic were performed.SettingThis study was performed in an in vitro animal model.PatientsThere were no patients involved in this study.Main Outcome MeasurementsAccuracy and reliability of pseudotumor volume measurement.ResultsWhen averaging across all measurements, the overall average mean error was 3.25%. The overall inter-rater reliability as measured by intraclass correlation coefficient was 0.78. The overall intra-rater reliability as measured by intraclass correlation coefficient was 0.99. Bland-Altman analysis and ANOVA showed similar low variability for measured volumes based on image frequencies for volume calculations between every other and every sixth image but greater variability for measured volumes based on every tenth image. Larger pseudotumors were measured with a slight decrease in mean percentage error. The kappa statistic for interobserver variability was .61, which demonstrated substantial agreement among observers.LimitationsThe major limitation of this technology is the penetration of the US beam to evaluate large tumors, because the US transducer is high frequency (20 MHz) and, therefore, has a limited penetration.ConclusionsIn conclusion, the new Olympus EUS EXERA EU-M60 3D US probe allowed for accurate volume measurements of small pseudotumors in porcine stomach model in vitro. There was substantial evaluator agreement, with a low interobserver variability. Larger pseudotumors were measured with a slightly lower percentage error than smaller pseudotumors. Volumes measured with a greater number of radial images were measured slightly more accurately. We plan to test this device in patients with GI tumors in the near future.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…