• Critical care medicine · Dec 1992

    Acute continuous hemofiltration with dialysis: effect on insulin concentrations and glycemic control in critically ill patients.

    • R Bellomo, P G Colman, J Caudwell, and N Boyce.
    • Department of Medicine, Monash Medical Centre, Parkville, Australia.
    • Crit. Care Med. 1992 Dec 1;20(12):1672-6.

    ObjectivesTo quantitate insulin losses and glucose absorption during acute continuous hemofiltration with dialysis and to assess the clinical importance of these changes.DesignProspective collection of serum and ultradiafiltrate fluid in patients receiving acute continuous hemofiltration with dialysis. Measurements of serum and ultradiafiltrate insulin and glucose concentrations. Calculations of insulin excretion and glucose absorption. Correlation of findings with patient outcome.SettingUniversity medical center.PatientsSixteen ICU patients with acute renal failure.Measurements And Main ResultsThe mean serum glucose concentration before acute continuous hemofiltration with dialysis was 178 mg/dL (9.9 mmol/L) (95% confidence interval 112 to 244 mg/dL [6.2 to 13.6 mmol/L]), increasing to 257 mg/dL (14.3 mmol/L) (95% confidence interval 167 to 347 mg/dL [9.3 to 19.3 mmol/L]) after 4 hrs of acute continuous hemofiltration with dialysis, and stabilizing at 207 mg/dL (11.5 mmol/L) (95% confidence interval 160 to 254 mg/dL [8.9 to 14.1 mmol/L]) at 24 hrs. Mean plasma insulin concentration before acute continuous hemofiltration with dialysis was 34.4 mU/L (95% confidence interval 8.6 to 60.2 mU/L), increasing to 54.4 mU/L at 4 hrs (95% confidence interval 25 to 83.8 mU/L; NS). There was no significant decrease in mean insulin concentration across the filter (51.8 mU/L before filtration vs. 51.9 mU/L after filtration). Insulin was detected in the ultradiafiltrate but its overall mean clearance rate was only 6.2 mL/min, with mean daily losses of 689 mU/day (95% confidence interval 325 to 1053 mU/day). During acute continuous hemofiltration with dialysis, glucose absorption through the filter averaged 134 g/day (95% confidence interval 96.2 to 171.8 g/day). Plasma insulin concentrations were significantly (p < .05) lower in survivors than nonsurvivors (51.7 vs. 123.6 mU/L).ConclusionsSignificant glucose absorption occurs during acute continuous hemofiltration with dialysis and is coupled with minor insulin losses (< 1 U/day) through the filter. These events do not appear to have major clinical impact. A low plasma insulin concentration is associated with diminished mortality rates in this group of patients.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…