• Critical care medicine · Jun 1998

    Comparative Study

    Mechanical performance of clinically available, neonatal, high-frequency, oscillatory-type ventilators.

    • D Hatcher, H Watanabe, T Ashbury, S Vincent, J Fisher, and A Froese.
    • Department of Anaesthesiology, Queen's University, Kingston, ON, Canada.
    • Crit. Care Med. 1998 Jun 1;26(6):1081-8.

    ObjectiveTo perform a functional evaluation of five different high-frequency, oscillatory-type ventilators that are currently being marketed for neonatal high-frequency oscillation.DesignObservational animal study.SettingLaboratory.SubjectsNew Zealand White male rabbits.InterventionsOscillator waveforms and delivered volumes were measured plethysmographically for the following ventilators: the SensorMedics 3100 A; the Dräger Baby Log 8000; the Metran Humming V; the Infant Star; and the Infant Star 950. The independent variables which were adjusted included frequency (5 to 15 Hz), amplitude (25% to 100%), mean airway pressure (5 to 25 cm H2O) and lung injury.Measurements And Main ResultsAt 15 Hz, the volume delivered at the 100% amplitude setting varied from 2.1 to 8.8 mL. Generally, the delivered volume decreased with increasing frequency, and with increased percentage of amplitude. Volume delivery was relatively unaffected by mean airway pressure but decreased with lung injury. Waveforms ranged from pure sinusoidal to a complex square wave. The handling of inspiration/expiration time ratios was ventilator specific. The SensorMedics inspiration/ expiration ratio is user selected over a range from 1:2.3 (30% inspiratory time) to 1:1 (50% inspiratory time) and once selected it is consistent over its entire range of operating frequencies. The Drager ratio is machine determined and varied from 1:2.5 at 5 Hz to 1:1 at 15 Hz. Inspiratory time of the Infant Star is machine set at 18 msecs such that the inspiration/expiration ratio is 1:10.1 at 5 Hz and 1:2.7 at 15 Hz. The Humming V has a fixed inspiration/expiration ratio of 1:1. The relationship of the mean airway pressure displayed on the ventilator to the alveolar occlusion pressure varied considerably among devices. The displayed mean pressure could either overestimate (SensorMedics at 33% inspiratory time or Infant Star), approximate (Humming V), or underestimate (Dräger) the mean lung distending pressure measured during a brief occlusion maneuver.ConclusionsThe findings demonstrate large variations in machine performance. The ventilators also differed profoundly in complexity of operation and versatility as neonatal ventilators.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…