- Bruce M Frankel, Sabino D'Agostino, and Chiang Wang.
- Department of Neurosurgery, Medical University of South Carolina, Charleston, South Carolina 29425, USA. frankel@musc.edu
- J Neurosurg Spine. 2007 Jul 1;7(1):47-53.
ObjectInstrumentation of the osteoporotic spine can be fraught with complications such as hardware failure. A cadaver study was performed to determine the biomechanical performance of polymethylmethacrylate (PMMA)-augmented pedicle screws.MethodsThree osteoporotic human cadaveric specimens with a mean bone mineral density of 0.70 g/cm2 were used to evaluate the performance of a novel fenestrated bone tap in pedicle screw augmentation. On this device, tap threads serve a dual purpose in preventing backflow of cement toward neural elements while allowing for a custom form for subsequent screw placement. The tap was used to inject a mean volume of 3.7 ml PMMA/pedicle (range 2-8.0 ml PMMA/pedicle) followed by pedicle screw placement between L-5 and T-5, alternating between augmented and nonaugmented instrumentation. Axial pullout testing was then performed.ResultsPedicle screw pullout strength was increased in both primary and salvage procedures by 119% (p = 0.001) and 162% (p = 0.01), respectively, after PMMA augmentation. Additionally, the injected cement volumes were divided into two groups, a low-cement group (< or = 2.8 ml/pedicle) and a high-cement group (> or = 5.5 ml/pedicle). Interestingly, the pullout strength did not significantly change with increased cement usage between the two groups (p > 0.05 for all comparisons).ConclusionsPolymethylmethacrylate-augmented pedicle screw fixation results in a significant increase in the axial pullout strength of augmented pedicle screws in both primary and revision procedures. This technique may be a valuable adjunct in cases in which bolstering of the screw-bone interface is necessary.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.