- Shiwei Xu, Meng Dai, Canhua Xu, Chaoshuang Chen, Mengxing Tang, Xuetao Shi, and Xiuzhen Dong.
- Department of Bioengineering, Fourth Military Medical University, Xi'an 710032, People's Republic of China.
- Ann Biomed Eng. 2011 Jul 1;39(7):2059-67.
AbstractElectrical impedance tomography (EIT) is an emerging medical imaging technique, which has already been investigated in several clinical applications due to its low-cost, non-invasiveness, non-radioactivity, high temporal resolution, and great sensitivity to impedance changes. One potential use of EIT is to perform long-term continuous imaging monitoring of brain for patients who suffer from severe cerebral diseases. However, this application requires a demanding performance of electrodes because of the characteristics of cerebral EIT measurements. Although Ag/AgCl bio-electrodes are widely used for clinical practices or EIT research at the moment, influences of different types of Ag/AgCl electrodes on cerebral EIT measurements have not been investigated. In this study, five common types of Ag/AgCl bio-electrodes were put into comparison by measuring the forearm and the brain of 10 healthy adult volunteers and evaluating those data in frequency or time domain in terms of contact impedance, uniformity, signal-to-noise ratio, and stability. Results show that Ag/AgCl powder electrode has an overall best performance with as low contact impedance as commercial ECG electrodes (p > 0.05), high SNR (60.3 ± 4.5 dB), better uniformity (coefficient of correlation 0.95 ± 0.03), and greater stability (slope 0.68 ± 0.03). After further improvement in design and instrumentation, Ag/AgCl powder electrode is likely to become the optimal choice for cerebral EIT measurements and provide feasible technical support for further research or application in cerebral EIT.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.