Randomized Controlled Trial Comparative Study Clinical Trial
Pulsatile and nonpulsatile extracorporeal circulation using Capiox E terumo oxygenator: a comparison study with Ultrox and Maxima membrane oxygenators.
- K Minami, A Bairaktaris, E Murray, H Weitkemper, W Dramburg, and R Körfer.
- Department of Thoracic and Cardiovascular Surgery, Heart Center North Rhine-Westfalia, University of Bochum, Germany.
- J Cardiovasc Surg. 1997 Jun 1;38(3):227-32.
AbstractAn open randomised, prospective study was undertaken on 90 patients who underwent routine myocardial revascularization. The aim of the study was to demonstrate that the Capiox E polypropylene fiber membrane oxygenator with a conventional single pulsatile/nonpulsatile blood pump for cardiopulmonary bypass (CPB) was comparable in performance to that of the Maxima and the Ultrox membrane oxygenators using a double pump system. The patients were divided into six groups according to perfusion mode and oxygenator type. Laboratory parameters, fluid balance and oxygenation was examined at set times before during and after cardiopulmonary bypass. Net fluid input was lower in the Capiox E groups regardless of perfusion mode: 2932 +/- 562 ml (Capiox E), compared to 3646 +/- 531 ml (Ultrox) and 3593 +/- 582 ml (Maxima). Net fluid balance 1288 +/- 534 ml was lowest in the Capiox/NP group, compared to 1604 +/- 460 ml (Ultrox/NP) and 1881 +/- 594 ml (Maxima/NP), (p < 0.05). The higher net fluid balance in the Capiox E/PP group 1649 +/- 580 ml compared to 1592 +/- 583 ml (Ultrox E/PP) and 1494 +/- 542 ml (Maxima/PP) was attributed to a technicality whereby the recommended priming volume of the Capiox E oxygenator was exceeded for safety reasons. The values of plasma free Hb were slightly higher in the PP than NP groups: Maxima/PP 80 mg/dl, /NP 50 mg/dl; Ultrox/PP 62 mg/dl, /NP 48 mg/dl; Capiox E/PP 55 mg/dl, /NP 48 mg/dl. The FiO2 was higher in the Capiox E groups 0.77 (PP) and 0.88 (NP) compared to Maxima/PP (0.66), /NP (0.65) and Ultrox/PP (0.64), /NP (0.63). Reciprocally, the venous saturation was higher in the Ultrox and Maxima groups compared to Capiox E at end of CPB. The study demonstrated that the CapioxE oxygenator with a single blood pump system can compare to the Maxima and Ultrox oxygenators with a double blood pump for CPB with regard to blood handling, oxygenation and fluid balance in routine cardiac surgery.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.