• Infect Control Hosp Epidemiol · Jan 1996

    Randomized Controlled Trial Clinical Trial

    Prospective, randomized study of ventilator-associated pneumonia in patients with one versus three ventilator circuit changes per week.

    • M N Long, G Wickstrom, A Grimes, C F Benton, B Belcher, and A M Stamm.
    • Department of Medicine, University of Alabama Hospital, Birmingham 35294, USA.
    • Infect Control Hosp Epidemiol. 1996 Jan 1;17(1):14-9.

    ObjectiveTo assess the effect on the rate of ventilator-associated pneumonia (VAP) of decreasing the frequency of ventilator circuit changes from three times to once per week.DesignProspective, randomized trial.SettingMedical intensive care unit (MICU), a 12-bed, critical-care internal medicine unit, and neurosciences intensive care unit (NICU), a 21-bed, predominantly adult neurosurgical unit, of an urban university hospital.PatientsAll 447 patients requiring mechanical ventilation during October 1992 through June 1993.InterventionPatients were allocated randomly on the basis of permanent medical record numbers: those with odd numbers had circuits changed three times per week, those with even numbers once per week. Intensive-care-unit surveillance was conducted in accordance with definitions and methods of the National Nosocomial Infections Surveillance System.ResultsIn the MICU, the one-change-per-week group had a VAP rate of 7.3 per 1,000 ventilator days, versus 5.9 for the three-per-week group (P = .6). In the NICU, the one-change-per-week group had a rate of 12.2 per 1,000 ventilator days, versus 12.6 for the three-per-week group (P = .9). Considering patients in both units ventilated for no more than 7 days, the one-change-per-week group had a VAP rate of 5.9 per 1,000 ventilator days, versus 9.0 per 1,000 for the three-changes-per-week group (odds ratio [OR], 0.65; 95% confidence interval [CI95], 0.25 to 1.69). Including patients in the two units maintained on mechanical ventilation for more than 7 days, the one-change-per-week group had a VAP rate of 13.2 per 1,000 ventilator days, versus 9.6 per 1,000 for the three-changes-per-week group (OR, 1.37; CI95, 0.71 to 2.65).ConclusionsDecreasing the frequency of ventilator circuit changes from three times to once per week had no adverse effect on the overall rate of VAP. Less frequent ventilator circuit changes may decrease the incidence of VAP among patients ventilated for no more than 1 week. However, the incidence of VAP may be higher among patients with once weekly circuit changes ventilated for more than 1 week.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…