-
Am. J. Physiol. Heart Circ. Physiol. · May 2007
Blind identification of the aortic pressure waveform from multiple peripheral artery pressure waveforms.
- Gokul Swamy, Qi Ling, Tongtong Li, and Ramakrishna Mukkamala.
- Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824, USA.
- Am. J. Physiol. Heart Circ. Physiol. 2007 May 1;292(5):H2257-64.
AbstractWe have developed a new technique to estimate the clinically relevant aortic pressure waveform from multiple, less invasively measured peripheral artery pressure waveforms. The technique is based on multichannel blind system identification in which two or more measured outputs (peripheral artery pressure waveforms) of a single-input, multi-output system (arterial tree) are mathematically analyzed so as to reconstruct the common unobserved input (aortic pressure waveform) to within an arbitrary scale factor. The technique then invokes Poiseuille's law to calibrate the reconstructed waveform to absolute pressure. Consequently, in contrast to previous related efforts, the technique does not utilize a generalized transfer function or any training data and is therefore entirely patient and time specific. To demonstrate proof of concept, we have evaluated the technique with respect to four swine in which peripheral artery pressure waveforms from the femoral and radial arteries and a reference aortic pressure waveform from the descending thoracic aorta were simultaneously measured during diverse hemodynamic interventions. We report that the technique reliably estimated the entire aortic pressure waveform with an overall root mean squared error (RMSE) of 4.6 mmHg. For comparison, the average overall RMSE between the peripheral artery pressure and reference aortic pressure waveforms was 8.6 mmHg. Thus the technique reduced the RMSE by 47%. As a result, the technique also provided similar improvements in the estimation of systolic pressure, pulse pressure, and the ejection interval. With further successful testing, the technique may ultimately be employed for more precise monitoring and titration of therapy in, for example, critically ill and hypertension patients.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.