-
- Jorge Alberto Castañón-González, Julián Satué-Rodríguez, Francisco Carrillo Rosales, Carlos Polanco-González, Rogelio Miranda-Ruíz, and Sergio Camacho-Juárez.
- Universidad Anáhuac, Huixquilucan, Estado de México, México. jorgec@prodigy.net.mx
- Cir Cir. 2013 Mar 1;81(2):112-7.
Introductionsequential measurement of intra-abdominal pressure is of paramount importance for an early detection and appropriate therapeutic management of intra-abdominal hypertension and abdominal compartment syndrome.Objectiveto validate a device and technique developed to measure intra-abdominal pressure (an innovation of the Foley urinary catheter named intra-abdominal pressure catheter).Methodsthree different sets of measurements where done to test the intra-abdominal pressure catheter device: I. 50 measurements were done with the intra-abdominal pressure catheter device and compared against those measurements done using a manometer graded in cm H(2)O; II. Direct measurement of intra-abdominal pressure in five patients during elective laparoscopy vs the intraabdominal pressure catheter device; and III. Measurement of intra-abdominal pressure by the Kron method (Gold standard) vs intra-abdominal pressure catheter device in three patents with intra-abdominal hypertension/abdominal compartment syndrome. Measurements where compared with Pearson correlation test and Bland Altman statistics.ResultsI.Intra-abdominal pressure catheter vs graded manometer: r = 0.99, with a mean pressure difference of 0.27 ± 0.23 mmHg, CI (0.039 to 0.092 mmHg). II. Direct measurement of intra-abdominal pressure during laparoscopy vs intra-abdominal pressure catheter device: r = 0.93, with a mean pressure difference of 0.18 ± 0.84 mmHg, CI (-1.46 to 1.83 mmHg) and III. Measurement of intra-abdominal pressure by the Kron Method vs intra-abdominal pressure catheter device: r = 0.81, with a mean pressure difference of -0.41 ± 0.87, CI (-2.12 mmHg to 1.30 mmHg).Conclusionsthe intra-abdominal pressure catheter device is a safe and reliable instrument for measuring intra-abdominal pressure.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.