    Clinical evaluation of target controlled infusion system for sufentanil administration.

    • Yan Zhao, Li-ping Zhang, Xin-min Wu, Jian-yu Jiang, Jing-li Duan, Yong-fang Hu, Min Li, Wei Liu, Xiao-yan Sheng, Cheng Ni, Mao Xu, and Xiang-yang Guo.
    • Department of Anesthesiology, Peking University Third Hospital, Beijing 100191, China.
    • Chinese Med J Peking. 2009 Oct 20;122(20):2503-8.

    BackgroundSufentanil target controlled infusion (TCI) provides stable analgesia, better hemodynamic control than a bolus injection of intravenous anesthetics, anticipated recovery and improved quality of anesthesia during perioperative period. This study evaluated the accuracy and feasibility of TCI system for sufentanil at high concentrations in Chinese surgical patients.MethodsTwelve low risk adult patients undergoing elective surgery under general anesthesia were included in this study. Sufentanil was administered with a specific TCI system incorporating the population pharmacokinetic data of sufentanil previously reported, using a target effect-site concentration of sufentanil 4 or 6 ng/ml. Sufentanil TCI duration was 30 minutes. Frequent arterial blood samples were taken during and up to 24 hours after sufentanil TCI for determination of plasma sufentanil concentrations by liquid chromatography-mass spectrometry/mass spectrometry. The changes of circulatory system function during the procedure, recovery profile and adverse effects were recorded. Measured plasma sufentanil concentrations were compared with the values predicted by the TCI system. The bias (median performance error, MDPE), precision (median absolute performance error, MDAPE) and wobble (variability of performance error) of the sufentanil TCI system were determined.ResultsAll patients had stable cardiovascular variables during induction and maintenance of anesthesia. Time to eye opening and extubation were (5.6 + or - 1.7) minutes when TCI set to 4 ng/ml and (7.2 + or - 2.3) minutes when set to 6 ng/ml. There was no episode of agitation, muscle rigidity or intraoperative awareness. The bias (MDPE), precision (MDAPE) and wobble of the sufentanil TCI system were -3.7%, 18.9% and 19.6% respectively during TCI, and the MDPE, MDAPE and wobble were -29.1%, 31.7% and 15.0% respectively after TCI (up to 8 hours).ConclusionsThe TCI system programmed for sufentanil at 4 or 6 ng/ml was considered acceptable for clinical use in low risk Chinese surgical patients. But the relatively larger MDPE and MDAPE after TCI suggest improvements of the pharmacokinetic model are needed.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.