Anesthesia and analgesia · Dec 2013
Comparative StudyPulse Wave Transit Time Measurements of Cardiac Output in Patients Undergoing Partial Hepatectomy: A Comparison of the esCCO System with Thermodilution.
- Masato Tsutsui, Yoshiyuki Araki, Kenichi Masui, Tomiei Kazama, Yoshihiro Sugo, Thomas L Archer, and Gerard R Manecke.
- From the *Department of Anesthesiology, National Defense Medical College, Saitama †Vital Sign Sensor Department, Monitoring Technology Center, Nihon Kohden Corporation, Tokyo, Japan; and ‡Department of Anesthesiology, University California, San Diego Medical Center, San Diego, California.
- Anesth. Analg.. 2013 Dec 1;117(6):1307-12.
BackgroundMeasuring cardiac output accurately during anesthesia is thought to be helpful for safely controlling hemodynamics. Several minimally invasive methods to measure cardiac output have been developed as alternatives to thermodilution with pulmonary artery catheterization. We evaluated the reliability of a novel pulse wave transit time method of cardiac output assessment to trend with thermodilution cardiac output in patients undergoing partial hepatectomy.MethodsThirty-one patients (ASA physical status II or III) undergoing partial hepatectomy under general anesthesia were evaluated. Cardiac output measurements by pulse wave transit time method and by thermodilution were recorded after induction of anesthesia, after a change in body positioning to 20° head up, after a change to 20° head down, after volume challenge with 10 mL·kg hydroxyethyl starch 6%, during the Pringle maneuver, and immediately after Pringle maneuver release. Trending was assessed using Bland-Altman analysis and concordance analysis.ResultsThe direction of change between consecutive pulse wave transit time measurements and the corresponding thermodilution measurements showed a concordance rate of 96.0% (lower 95% confidence interval = 64%), with limits of agreement -1.51 and 1.61 L·min.ConclusionsThe pulse wave transit time method had good concordance but fairly wide limits of agreement with regard to trending in patients with changes in preload and systemic vascular resistance. There are potential inaccuracies when vasopressors are used to treat hypotension associated with decreased systemic vascular resistance. The study limitations are that the cardiac output data were collected in a nonblinded fashion, and an existing intraarterial catheter was used, although the system requires only routine, noninvasive cardiovascular monitors. This is a promising technique that currently has limitations and will require further improvements and clinical assessment.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.