    Tracheal palpation to assess endotracheal tube depth: an exploratory study.

    • William P McKay, Jim Klonarakis, Vladko Pelivanov, Jennifer M O'Brien, and Chris Plewes.
    • Department of Anesthesia, RUH, University of Saskatchewan, 103 Hospital Dr., Saskatoon, SK, S7N 0W8, Canada, bill.mckay@usask.ca.
    • Can J Anaesth. 2014 Mar 1;61(3):229-34.

    PurposeCorrect placement of the endotracheal tube (ETT) occurs when the distal tip is in mid-trachea. This study compares two techniques used to place the ETT at the correct depth during intubation: tracheal palpation vs placement at a fixed depth at the patient's teeth.MethodsWith approval of the Research Ethics Board, we recruited American Society of Anesthesiologists physical status I-II patients scheduled for elective surgery with tracheal intubation. Clinicians performing the tracheal intubations were asked to "advance the tube slowly once the tip is through the cords". An investigator palpated the patient's trachea with three fingers spread over the trachea from the larynx to the sternal notch. When the ETT tip was felt in the sternal notch, the ETT was immobilized and its position was determined by fibreoptic bronchoscopy. The position of the ETT tip was compared with our hospital standard, which is a depth at the incisors or gums of 23 cm for men and 21 cm for women. The primary outcome was the incidence of correct placement. Correct placement of the ETT was defined as a tip > 2.5 cm from the carina and > 3.5 cm below the vocal cords.ResultsMovement of the ETT tip was readily palpable in 77 of 92 patients studied, and bronchoscopy was performed in 85 patients. Placement by tracheal palpation resulted in more correct placements (71 [77%]; 95% confidence interval [CI] 74 to 81) than hospital standard depth at the incisors or gums (57 [61%]; 95% CI 58 to 66) (P = 0.037). The mean (SD) placement of the ETT tip in palpable subjects was 4.1 (1.7) cm above the carina, 1.9 cm (1.5-2.3 cm) below the ideal mid-tracheal position.ConclusionTracheal palpation requires no special equipment, takes only a few seconds to perform, and may improve ETT placement at the correct depth. Further studies are warranted.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…