Critical care medicine · Mar 1994
Optimal release time during airway pressure release ventilation in neonatal sheep.
- L D Martin and R C Wetzel.
- Department of Anesthesiology/Critical Care Medicine, Johns Hopkins Medical Institutions, Baltimore, MD.
- Crit. Care Med. 1994 Mar 1;22(3):486-93.
ObjectiveTo systematically investigate the effect of altering release time during airway pressure release ventilation in a neonatal animal model before and after oleic acid-induced acute lung injury.DesignProspective, nonrandomized, controlled study with repeated measures.SettingUniversity research laboratory.SubjectsEight neonatal sheep (aged < 7 days, weight 5.1 +/- 0.3 kg).InterventionsThroughout this study, airway pressure release ventilation was performed with an FIO2 of 0.21 at a frequency of 0.5 Hz (30 breaths/min) and an airway plateau pressure set to deliver tidal volumes between 10 and 15 mL/kg with a release time of 1 sec. Release time was changed in decrements of 0.2 sec starting at 1 sec and ending at 0.2 sec at 10-min intervals. Cardio-respiratory profiles were recorded at the end of each interval. The total exhaled respiratory system time constant (tau) was measured by plotting exhaled volume (integration of exhaled air flow) vs. time. Acute lung injury was induced by oleic acid infusion. The protocol was repeated with increased plateau airway pressure to maintain tidal volumes between 10 and 15 mL/kg at a release time of 1 sec.Measurements And Main ResultsDuring airway pressure release ventilation at a release time of 1 sec, oleic acid-induced acute lung injury decreased dynamic lung compliance (9.9 +/- 2.2 vs. 7.5 +/- 2.0 mL/cm H2O, p < .01), the expiratory time constant (0.15 +/- 0.04 vs. 0.12 +/- 0.02 sec, p < .05), and mean arterial pressure (80 +/- 5 vs. 62 +/- 12 mm Hg, p < .01). Alveolar ventilation was maintained as long as release times were > 0.4 sec (approximately 3 tau or greater). PaO2 decreased with release times of < 0.3 sec, but the alveolar-arterial oxygen tension difference was unchanged. In this protocol, with higher plateau and mean airway pressures, oleic acid-induced acute lung injury had no effect on the relationship between release time and oxygenation or ventilation.ConclusionsIn this neonatal laboratory model, release times that were much shorter than previously reported maintained clinically acceptable oxygenation and ventilation. The optimal duration of the release time is a function of the time constant of the respiratory system. During airway pressure release ventilation, alveolar ventilation was maintained without apparent lung volume loss with release times of between 4 tau and 10 tau.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.