    Maintenance of airway pressure during filter exchange via autotrigging of mechanical ventilator.

    • Joakim Engström, Henrik Reinius, Camilla Fröjd, Jonsson Hans, Göran Hedenstierna, and Anders Larsson.
    • Respir Care. 2014 Aug 1;59(8):1210-7.

    BackgroundDaily routine ventilator-filter exchange interrupts the integrity of the ventilator circuit. We hypothesized that this might reduce positive airway pressure in mechanically ventilated ICU patients, inducing alveolar collapse and causing impaired oxygenation and compliance of the respiratory system.MethodsWe studied 40 consecutive ICU subjects (P(aO2)/F(IO2) ratio ≤ 300 mm Hg), mechanically ventilated with pressure-regulated volume control or pressure support and PEEP ≥ 5 cm H2O. Before the filter exchange, (baseline) tidal volume, breathing frequency, end-inspiratory plateau pressure, and PEEP were recorded. Compliance of the respiratory system was calculated; F(IO2), blood pressure, and pulse rate were registered; and P(aO2), P(aCO2), pH, and base excess were measured. Measurements were repeated 15 and 60 min after the filter exchange. In addition, a bench test was performed with a precision test lung with similar compliance and resistance as in the clinical study.ResultsThe exchange of the filter took 3.5 ± 1.2 s (mean ± SD). There was no significant change in P(aO2) (89 ± 16 mm Hg at baseline vs 86 ± 16 mm Hg at 15 min and 88 ± 18 mm Hg at 60 min, P = .24) or in compliance of the respiratory system (41 ± 11 mL/cm H2O at baseline vs 40 ± 12 mL/cm H2O at 15 min and 40 ± 12 mL/cm H2O at 60 min, P = .32). The bench study showed that auto-triggering by the ventilator when disconnecting from the expiratory circuit kept the tracheal pressure above PEEP for at least 3 s with pressure controlled ventilation.ConclusionsThis study showed that a short disconnection of the expiratory ventilator circuit from the ventilator during filter exchange was not associated with any significant deterioration in lung function 15 and 60 min later. This result may be explained by auto-triggering of the ventilator with high inspiratory flows during the filter exchange, maintaining airway pressure.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…